2018
DOI: 10.1038/s41433-018-0068-5
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of long-term decentration and tilt in two types of multifocal intraocular lenses with OPD-Scan III aberrometer

Abstract: Both MfIOLs significantly improve the visual acuity of the patients. However, tilt was lower in the SN6AD1 group than in the ZMB00 group 1 year after surgery, which provide fewer HOAs and better visual quality.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
16
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 24 publications
(16 citation statements)
references
References 28 publications
0
16
0
Order By: Relevance
“…An OPD-Scan III aberrometer provided the total and intraocular high-order aberration (HOA) data, including the Strehl ratio, with a mesopic pupil under mesopic (3 cd/m2) lighting conditions [11]. The OPD-Scan III provides a complete set of maps, including four different corneal topography maps, local refractive power of the entire eye due to aberrations at various locations within the pupil, a variety of wavefront aberration maps, and photopic and mesopic pupillometry.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…An OPD-Scan III aberrometer provided the total and intraocular high-order aberration (HOA) data, including the Strehl ratio, with a mesopic pupil under mesopic (3 cd/m2) lighting conditions [11]. The OPD-Scan III provides a complete set of maps, including four different corneal topography maps, local refractive power of the entire eye due to aberrations at various locations within the pupil, a variety of wavefront aberration maps, and photopic and mesopic pupillometry.…”
Section: Methodsmentioning
confidence: 99%
“…Wavefront data are gathered from available zones up to a 9.5 mm area including 2,520 data point analyses, in 7 zone measurement, adding the capability to provide for the calculation of mesopic refractions. Placido disc topography measures 33 rings in a vertical position and 39 in the horizontal position, including 11,880 data points [11].…”
Section: Methodsmentioning
confidence: 99%
“…Misalignment of the intraocular lens (IOL) is an important risk factor for the deterioration of visual quality after cataract surgery. Previous studies have found that an IOL tilt greater than 7° or decentration greater than 0.4 mm affects visual quality after IOL implantation by increasing wavefront aberrations, such as astigmatism and high-order aberrations (HOA) (1)(2)(3). Especially for toric and multifocal IOLs, their optical performances were more sensitive to tilt and decentration.…”
Section: Introductionmentioning
confidence: 99%
“…evaluated the clinical effect of misalignments in multifocal IOLs. 12,[20][21][22] Probably, centration or tilting of all IOLs with complex designs would affect both AR and MR. Thus, it would be interesting to analyze if misalignments significantly affect the AR and MR with trifocals and if the effect becomes more dramatic with trifocal toric IOLs.…”
Section: Discussionmentioning
confidence: 99%