2007
DOI: 10.1016/j.jhazmat.2006.12.027
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of linear and nonlinear analysis in estimating the Thomas model parameters for methylene blue adsorption onto natural zeolite in fixed-bed column

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

5
72
0
4

Year Published

2011
2011
2022
2022

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 219 publications
(90 citation statements)
references
References 39 publications
5
72
0
4
Order By: Relevance
“…La selección del modelo más adecuado se basó en los criterios de mejor ajuste y menor error registrado. Para el procesamiento de los datos se utilizó el programa de Microsoft Office Excel y el complemento de optimización Solver [14,15].…”
Section: Análisis De Errorunclassified
“…La selección del modelo más adecuado se basó en los criterios de mejor ajuste y menor error registrado. Para el procesamiento de los datos se utilizó el programa de Microsoft Office Excel y el complemento de optimización Solver [14,15].…”
Section: Análisis De Errorunclassified
“…The first ones are the non-structural models which may agree quite well with the experimental data; nonetheless, these do not include parameters describing adsorbent structure and are thus more or less of an interpolative nature. Among these are the Thomas model (Han et al, 2007) and models based on the law of mass action (Moraes et al, 2009;Papini et al, 1999), applied to a wide range of adsorption processes of metals (Papini et al, 1999), heterocyclic compounds (Han et al, 2007), and enzymes (Moraes et al, 2009). The second subgroup are the structural models, which usually also agree quite well with experimental data and include parameters describing adsorbent structure such as adsorbent particle size (Dadwhal et al, 2009;Forrer et al, 2008;Quek and Al-Duri, 2007), micro-particle size (Dadwhal et al, 2009), particle size distribution (Du et al, 2007) or other characteristic dimensions (Zabka et al, 2006), and are thus more of an extrapolative nature.…”
Section: Introductionmentioning
confidence: 99%
“…Embora o método dos mínimos quadrados não lineares seja considerado mais preciso do que o método linear, quando aplicados à modelagem dos dados de colunas de adsorção (HAN et al, 2007), alguns trabalhos recentes continuam empregando a análise linear, demonstrando que o mesmo também pode descrever adequadamente a adsorção de amônia em zeólitas (ZHENG et al, 2008). Assim, tanto o método linear como não linear foram testados no presente estudo para fins comparativos.…”
Section: Remoção De Amônia De Efluentes Reaisunclassified