PsycEXTRA Dataset 2005
DOI: 10.1037/e456352006-001
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of human responses to prototype and standard uniforms using three different human simulation models: HSDA, Scenario_J and Simulink2NM

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
8
0

Year Published

2007
2007
2022
2022

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(9 citation statements)
references
References 1 publication
(2 reference statements)
1
8
0
Order By: Relevance
“…A skin temperature of 36°C (SHAP 36 ) is most often selected. This is a good approximation under heat stress conditions and in accordance with progenitor papers (Givoni and Goldman 1972) of the SHAP algorithm and the purposes of models that followed (Berglund and Yokota 2005;Pandolf et al 1986), but its accuracy when generalized across cooler conditions when skin temperatures are lower (Departments of the Army and Air Force 2003;IOM 2005;Montain et al 1999) remains unknown.…”
Section: Introductionsupporting
confidence: 53%
See 3 more Smart Citations
“…A skin temperature of 36°C (SHAP 36 ) is most often selected. This is a good approximation under heat stress conditions and in accordance with progenitor papers (Givoni and Goldman 1972) of the SHAP algorithm and the purposes of models that followed (Berglund and Yokota 2005;Pandolf et al 1986), but its accuracy when generalized across cooler conditions when skin temperatures are lower (Departments of the Army and Air Force 2003;IOM 2005;Montain et al 1999) remains unknown.…”
Section: Introductionsupporting
confidence: 53%
“…The algorithm is the same for both SHAP and SHAP 36 . What differs between them is that SHAP 36 sets T sk to 36°C and P sk to 44 mmHg (Berglund and Yokota 2005;Givoni and Goldman 1972), while SHAP uses actual (measured) values of T sk (Shapiro et al 1982).…”
Section: Measurements and Calculationsmentioning
confidence: 99%
See 2 more Smart Citations
“…Numerous metrics are based upon direct physiological responses within humans and animals; however, almost all of them are complicated algorithms (e.g., Moran et al, 2001; Berglund and Yokota, 2005;Gribok et al, 2008;Maloney and Forbes, 2011;Havenith et al, 2011;Gonzalez et al, 2012;Chan et al, 2012). Most metrics require radiation measurements or heart rates, and/or even sweat rates.…”
Section: Physiology Algorithmsmentioning
confidence: 99%