2008
DOI: 10.1016/j.joen.2008.03.015
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of Forces Generated During Root Canal Shaping and Residual Stresses of Three Nickel–Titanium Rotary Files by Using a Three-Dimensional Finite-element Analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

2
82
0

Year Published

2009
2009
2024
2024

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 93 publications
(89 citation statements)
references
References 39 publications
2
82
0
Order By: Relevance
“…The ProTaper Universal file with a reduced bending moment and increased flexibility was launched recently as an improvement to the original design. A mathematical simulation found that stress concentration was situated at the trailing edge adjacent to rather than at the cutting edge on the ProTaper Universal file (20). In theory, this could help to alleviate the combined effect of having both the greatest stress concentration and the site of rubbing contact with the root canal wall at the same location.…”
Section: Discussionmentioning
confidence: 99%
“…The ProTaper Universal file with a reduced bending moment and increased flexibility was launched recently as an improvement to the original design. A mathematical simulation found that stress concentration was situated at the trailing edge adjacent to rather than at the cutting edge on the ProTaper Universal file (20). In theory, this could help to alleviate the combined effect of having both the greatest stress concentration and the site of rubbing contact with the root canal wall at the same location.…”
Section: Discussionmentioning
confidence: 99%
“…These areas are especially vulnerable if those with the highest levels of stress coincide with the presence of machining marks or miniature grooves (16). Once the cracks are nucleated, their growth progresses slowly and seemingly along these machining grooves, at least initially, until the sudden, final fracture occurs (17,18).…”
Section: Discussionmentioning
confidence: 99%
“…NiTi rotary files are available in a variety of designs, each with features that affect the manner in which they engage and cut dentin (7) and the stress that may generate within them (8,9). The safety of NiTi instruments in use requires an understanding of the basic mechanism for the development of defect and the factors involved (10,11).…”
mentioning
confidence: 99%