2010
DOI: 10.1590/s1807-59322010000500003
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of five portable peak flow meters

Abstract: OBJECTIVETo compare the measurements of spirometric peak expiratory flow (PEF) from five different PEF meters and to determine if their values are in agreement. Inaccurate equipment may result in incorrect diagnoses of asthma and inappropriate treatments.METHODSSixty-eight healthy, sedentary and insufficiently active subjects, aged from 19 to 40 years, performed PEF measurements using Air Zone®, Assess®, Galemed®, Personal Best® and Vitalograph® peak flow meters. The highest value recorded for each subject for… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
11
1

Year Published

2011
2011
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 19 publications
(12 citation statements)
references
References 21 publications
0
11
1
Order By: Relevance
“…The physical therapy intervention consisted by postural correction and respiratory reeducation with stretching of inspiratory accessory muscles and abdominal muscles reinforcement may contribute to reduce the work of cervical muscles during the inspiration. Thereby, decreasing the respiratory effort by the of asthma symptoms (27). The occurrence of asthma was not reported by the subjects of the present study, what may explain the lack of difference in the peak of expiratory flow values between the groups.…”
Section: Discussioncontrasting
confidence: 53%
“…The physical therapy intervention consisted by postural correction and respiratory reeducation with stretching of inspiratory accessory muscles and abdominal muscles reinforcement may contribute to reduce the work of cervical muscles during the inspiration. Thereby, decreasing the respiratory effort by the of asthma symptoms (27). The occurrence of asthma was not reported by the subjects of the present study, what may explain the lack of difference in the peak of expiratory flow values between the groups.…”
Section: Discussioncontrasting
confidence: 53%
“…The PEFR values by spirometer and mini-Wright Peak Flow Meter correlate well with each other with very little difference as demonstrated by other studies. 3,4 However, other studies (Takara et al 5 ) have shown conflicting results and demonstrate no agreement between the spirometric values and values obtained with peak flow meter. The lack of agreement between the spirometric values and the values obtained from the meter does not indicate that they lack validity or perform poorly; it only indicates that the meters cannot replace the PEFR spirometric measurements.…”
Section: Discussionmentioning
confidence: 93%
“…Lately, electronic versions have appeared with the added benefits of accuracy and record tracking. Several reports [5], [6] that these devices fail to provide concordant measurements and no ageing studies exist to certify robustness of operation with usage. Philips-Respironics Assess Peak Flow Meter that is operated pneumatically and the smartphone enabled MySpiroo (under development) are two indicative devices.…”
Section: Personalising Respiratory Healthmentioning
confidence: 99%