Comparison of Eye Lens Dose on Neuroimaging Protocols between 16- and 64-Section Multidetector CT: Achieving the Lowest Possible Dose

Abstract: BACKGROUND AND PURPOSE: To our knowledge, there has been no study that compares the radiation dose delivered to the eye lens by 16-and 64-section multidetector CT (MDCT) for standard clinical neuroimaging protocols. Our aim was to assess radiation-dose differences between 16-and 64-section MDCT from the same manufacturer, by using near-identical neuroimaging protocols.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
17
0
1

Year Published

2012
2012
2019
2019

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 33 publications
(19 citation statements)
references
References 16 publications
(16 reference statements)
1
17
0
1
Order By: Relevance
“…These results are already comparable to average eye lens dose achieved in non-helical CT scans performed in tilted axial mode: 18.1 ± 7.6 mGy with automatic tube current modulation switched off and 15.6 ± 4.2 mGy with automatic tube current modulation switched on 12 . This is also the first study on patients in routine clinical settings, based on eye lens dose calculations in head MDCT protocols utilizing IR algorithms.…”
supporting
confidence: 73%
See 2 more Smart Citations
“…These results are already comparable to average eye lens dose achieved in non-helical CT scans performed in tilted axial mode: 18.1 ± 7.6 mGy with automatic tube current modulation switched off and 15.6 ± 4.2 mGy with automatic tube current modulation switched on 12 . This is also the first study on patients in routine clinical settings, based on eye lens dose calculations in head MDCT protocols utilizing IR algorithms.…”
supporting
confidence: 73%
“…The achieved effective and organ doses in our study population are at the very low end of published ranges 1,[11][12][25][26][27][28] . Albeit undoubtedly beneficial from the radiation safety point of view, the study might have limitations, namely decreased image quality and the inferior diagnostic performance of such scans.…”
mentioning
confidence: 71%
See 1 more Smart Citation
“…However, the increase of CT testing is suspected to be a cause of the rising rate of carcinogenesis. It is already known that even low dose scans can occasionally cause leukemia, breast cancer, thyroid cancer, lung cancer, and other cancers [6,7].…”
Section: Introductionmentioning
confidence: 99%
“…At this time, the radiation dose loaded upon the head of patients is reported to be about 50 mGy of which about 1.5% * 2% directly affects the eyes [6,11].…”
Section: Introductionmentioning
confidence: 99%