2020
DOI: 10.3174/ajnr.a6483
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of Enhancement of the Vestibular Perilymph between Variable and Constant Flip Angle–Delayed 3D-FLAIR Sequences in Menière Disease

Abstract: BACKGROUND AND PURPOSE: Endolymphatic hydrops in patients with Menière disease relies on delayed postcontrast 3D-FLAIR sequences. The purpose of this study was to compare the degree of perilymphatic enhancement and the detection rate of endolymphatic hydrops using constant and variable flip angles sequences. MATERIALS AND METHODS:This was a retrospective study performed in 16 patients with Menière disease who underwent 3T MR imaging 4 hours after gadolinium injection using two 3D-FLAIR sequences with a constan… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
12
1

Year Published

2020
2020
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(14 citation statements)
references
References 30 publications
1
12
1
Order By: Relevance
“…After assessing the abstract and title, full-text evaluation, and quality assessment (results in appendix C), 30 eligible articles were included in the review (Fig. 1) (1948).…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…After assessing the abstract and title, full-text evaluation, and quality assessment (results in appendix C), 30 eligible articles were included in the review (Fig. 1) (1948).…”
Section: Resultsmentioning
confidence: 99%
“…The remaining two studies were animal studies in which IV administration was used (19–30). There were 15 studies on PL of the inner ear and three phantom studies (3148).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…A number of technical innovations have been recently added to the MR armamentarium to improve the identification of EH, such as the Variable and Constant Flip Angle-Delayed 3D-FLAIR Sequences ( 44 ) or the i.t.-Gd “ medium inversion time inversion recovery imaging with magnitude reconstruction ” (MIIRMR) ( 65 ).…”
Section: Discussionmentioning
confidence: 99%
“…The high-resolution, strongly T2weighted, 3D constructive interference steady state (CISS) sequence of the temporal bones was performed to evaluate the anatomy of the whole-fluid-filled labyrinthine spaces and had the following parameters: TR 1,000 ms, TE 133 ms, FA 100 • , FOV 192 × 192 mm 2 , 56 slices, base resolution 384, averages 4, acceleration factor of 2 using GRAPPA algorithm, slice thickness of 0.5 mm and acquisition time 8:36 min. The presence of ELH was observed on the 3D-FLAIR images as enlarged negativesignal spaces inside the labyrinth, according to a previously reported method (18,46).…”
Section: Data Acquisitionmentioning
confidence: 99%