Comparison of different methods of DatSCAN quantification

Abstract: Both programs allowed statistical differentiation between Parkinson's syndrome and essential tremor. Strict operator protocols are needed with QuantiSPECT to reduce inter- and intra-operator variation. The three-dimensional method (BRASS) gave greater concordance than the two-dimensional method (QuantiSPECT) with the visual assessment, but at a cost of increased operator time.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
41
0
18

Year Published

2007
2007
2020
2020

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 48 publications
(60 citation statements)
references
References 10 publications
1
41
0
18
Order By: Relevance
“…Mid-putaminal VOIs probably offer the most accurate manual results. Automated VOI systems incorporating the whole striatum using individualized VOIs, either based on the 123 I-ioflupane SPECT data or on a coregistered anatomic scan, produce more objective, observer-independent results and are faster although not widespread (32)(33)(34)(35).…”
Section: Semiquantificationmentioning
confidence: 99%
“…Mid-putaminal VOIs probably offer the most accurate manual results. Automated VOI systems incorporating the whole striatum using individualized VOIs, either based on the 123 I-ioflupane SPECT data or on a coregistered anatomic scan, produce more objective, observer-independent results and are faster although not widespread (32)(33)(34)(35).…”
Section: Semiquantificationmentioning
confidence: 99%
“…This software has been shown to provide consistent results independent of operator variability [10]. BRASS fits the patient data to a pre-existing template containing a number of volumes of interest (VOIs) and calculates the caudate and putamen uptake ratios (CUR and PUR respectively), where C, P and B are the average counts per voxel in the caudate nucleus, putamen and background regions, respectively.…”
Section: Scan Quantificationmentioning
confidence: 99%
“…A number of software packages exist that allow quantification of uptake in the striata [5] and different methods of quantification exist and have been compared [6]. Quantification has been shown to reduce interobserver variability in scan reporting [7] and to correlate with visual assessment [8], however to our knowledge no studies have specifically studied whether quantification can reduce the number of scans reported as equivocal.…”
Section: Introductionmentioning
confidence: 99%
“…Other investigators have focused on brain image-processing packages (17)(18)(19)(20)(21)26). In its application, OSA most closely resembles the automated analysis package reported by Koch et al (20,21).…”
Section: Discussionmentioning
confidence: 99%
“…Other investigators have developed methods to quantitate the uptake level of DATs by analyzing the associated SPECT scans (17)(18)(19)(20)(21). In this study, we tested an automated DATimaging objective striatal analysis (OSA) program specifically for 123 I-b-CIT in a large clinical cohort and compared the results with a well-established manual analysis by a trained image-processing technologist.…”
mentioning
confidence: 99%