2006
DOI: 10.1016/j.ophtha.2006.01.063
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of Central Corneal Thickness Measurements by Rotating Scheimpflug Camera, Ultrasonic Pachymetry, and Scanning-Slit Corneal Topography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

7
104
5
4

Year Published

2008
2008
2016
2016

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 159 publications
(120 citation statements)
references
References 14 publications
7
104
5
4
Order By: Relevance
“…[12][13][14] In this study, corneal topography (Allegro Oculyzer, WaveLight AG, Erlangen, Germany) was conducted with undilated pupils under scotopic conditions by a single experienced technician. Scans were taken in automatic mode with proper quality.…”
Section: Examinationsmentioning
confidence: 99%
See 1 more Smart Citation
“…[12][13][14] In this study, corneal topography (Allegro Oculyzer, WaveLight AG, Erlangen, Germany) was conducted with undilated pupils under scotopic conditions by a single experienced technician. Scans were taken in automatic mode with proper quality.…”
Section: Examinationsmentioning
confidence: 99%
“…Maximum keratometry and corneal pachymetry at the thinnest location were recorded at baseline and 1 year after CXL treatment. 13,14 Cone location was determined according to the topographic coordinates of maximum keratometry as follows: central cone (maximum K within the central 3 mm optical zone), paracentral cone (3-5 mm optical zone), and peripheral cone (outside the central 5 mm optical zone).…”
Section: Examinationsmentioning
confidence: 99%
“…Corneal thickness is important to informed the corneal endothelial cell function, patient candidate of cataract and refractive surgery, and can affect intraocular pressure measurement by Goldmann applanation tonometry becoming an independent risk factor for glaucoma progression (1)(2)(3)(4)(5)(6) . Variations on mesasuremnts represents an important problem because failure to do so may result in misclassification and, thus, an inaccurate assignment of risk.…”
Section: Discussionmentioning
confidence: 99%
“…However, the rotating Scheimpflug camera (Pentacam, Oculus, Inc., Wetzlar, Germany) is considered to be one of the most reliable devices that measures CCT values comparable to ultrasound corneal pachymetry instruments [19,20,21].…”
Section: Introductionmentioning
confidence: 99%