1999
DOI: 10.1002/(sici)1522-2683(19991001)20:14<2909::aid-elps2909>3.0.co;2-m
|View full text |Cite
|
Sign up to set email alerts
|

Comparison between transient isotachophoretic capillary zone electrophoresis and reversed-phase liquid chromatography for the determination of peptides in plasma

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2000
2000
2001
2001

Publication Types

Select...
6
1

Relationship

3
4

Authors

Journals

citations
Cited by 22 publications
(13 citation statements)
references
References 31 publications
0
13
0
Order By: Relevance
“…ITP has been used on-line to enhance the limit of detection for CZE-MS [17]. The sensitivity of ITP-CZE has been found comparable to that of LC for the analysis of peptide drugs in plasma [18]. ITP analysis has been combined with NMR detection both in continuous-flow and stopped-flow modes [19].…”
Section: Preconcentrationmentioning
confidence: 99%
“…ITP has been used on-line to enhance the limit of detection for CZE-MS [17]. The sensitivity of ITP-CZE has been found comparable to that of LC for the analysis of peptide drugs in plasma [18]. ITP analysis has been combined with NMR detection both in continuous-flow and stopped-flow modes [19].…”
Section: Preconcentrationmentioning
confidence: 99%
“…three orders of magnitude in comparison with normal CZE. tITP has been utilized for the determination of both peptides [12][13][14] and proteins [15]. Today, with tITP a concentration sensitivity about the same as in conventional HPLC can be reached.…”
Section: Electrophoresis-based Preconcentrationmentioning
confidence: 99%
“…As sample preparation technique an SPE procedure is employed, based on a cation-exchange mechanism. This SPE procedure is earlier, in somewhat modified form, efficiently applied as sample preparation procedure prior to transient isotachophoresis CE [18] and liquid chromatography with fluorescence detection [37].…”
Section: On-capillary Preconcentrating Ce-uvmentioning
confidence: 99%
“…However, CE has intrinsic poor concentration sensitivity, due to a low loading capacity. Several solutions have been brought up to increase the sample loadability without loss of resolution, such as field-amplified sample stacking [2][3][4][5][6], transient isotachophoresis [7][8][9][10][11][12][13][14][15][16][17][18][19], and on-capillary preconcentration on a stationary phase [20][21][22][23][24][25][26][27][28][29][30][31]. The on-capillary preconcentration has the benefit that sample loading is not limited to the capillary volume and that on-line purification of the applied sample can be accomplished by employing washing steps.…”
Section: Introductionmentioning
confidence: 99%