2001
DOI: 10.1080/03067310108044348
|View full text |Cite
|
Sign up to set email alerts
|

Comparison between Total Determination and Extractable Heavy Metals from River Sediments using Conventional and Microwave Accelerated Leaching Tests

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2008
2008
2023
2023

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(2 citation statements)
references
References 17 publications
0
2
0
Order By: Relevance
“…In addition, Wang et al [10,21] reported elemental recoveries of 77-186% when coal samples were digested using microwave and concentrated acidic solutions (HNO 3 -H 2 O 2 and HNO 3 only) without HF, HCl and HClO 4 addition. Due to the growing interest towards the implementation of 'Green Chemistry' principles, several studies revealed the use of diluted inorganic acids for extraction of trace elements in solid matrices and recoveries of 89-117% were attained [22][23][24][25][26][27][28][29]. The current study aimed at developing a sample preparation method based on the use of diluted HNO 3 -H 2 O 2 mixture and microwave radiation for rapid extraction of trace elements in coal samples prior to ICP-MS determination.…”
Section: Introductionmentioning
confidence: 99%
“…In addition, Wang et al [10,21] reported elemental recoveries of 77-186% when coal samples were digested using microwave and concentrated acidic solutions (HNO 3 -H 2 O 2 and HNO 3 only) without HF, HCl and HClO 4 addition. Due to the growing interest towards the implementation of 'Green Chemistry' principles, several studies revealed the use of diluted inorganic acids for extraction of trace elements in solid matrices and recoveries of 89-117% were attained [22][23][24][25][26][27][28][29]. The current study aimed at developing a sample preparation method based on the use of diluted HNO 3 -H 2 O 2 mixture and microwave radiation for rapid extraction of trace elements in coal samples prior to ICP-MS determination.…”
Section: Introductionmentioning
confidence: 99%
“…fast way of desorbing inorganic 58,73,77 and organic pollutants 78 from sediments, soil and biological samples. 79,80 Ultrasound extraction is also an aseptic method and it has been suggested that high frequency ultrasound (20 kHz) in low volumes (200 mL) of bacterial suspensions resulted in a continuous reduction of bacterial cell numbers.…”
Section: Ultrasound Extractionmentioning
confidence: 99%