All Days 1983
DOI: 10.2118/11973-ms
|View full text |Cite
|
Sign up to set email alerts
|

Comparison and Analysis of Reservoir Rocks and Related Clays

Abstract: A series of instrumental and chemical analyses was made to determine the surface chemical properties of sedimentary rocks and the physical characteristics of the pores. A scanning electron microscope (SEM) with energy dispersive X-ray analytic capability was used to study the morphology of the samples, surface mineral composition and type and location of clays. A centrifuge was used to determine the pore size distributions which are correlated with the SEM observations. An inductively coupled plasma (ICP) was … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
4
0

Year Published

1986
1986
2021
2021

Publication Types

Select...
4
2
2

Relationship

0
8

Authors

Journals

citations
Cited by 22 publications
(5 citation statements)
references
References 1 publication
1
4
0
Order By: Relevance
“…In all cases, the total amount of elemental oxides detected was near 100% of the total oxide measured in the sample so that if other ions were present they would be in very small quantities. These data are consistent with a change in porosity after autoclaving because a reduction in silica content indicates a loss in cementation between clays and the grain particles (4). Furthermore, decreases in the amounts of aluminum and potassium in autoclaved core samples are also consistent with a loss in clay content since clays are composed of these elements.…”
Section: Donaldson Personal Communication)supporting
confidence: 78%
See 2 more Smart Citations
“…In all cases, the total amount of elemental oxides detected was near 100% of the total oxide measured in the sample so that if other ions were present they would be in very small quantities. These data are consistent with a change in porosity after autoclaving because a reduction in silica content indicates a loss in cementation between clays and the grain particles (4). Furthermore, decreases in the amounts of aluminum and potassium in autoclaved core samples are also consistent with a loss in clay content since clays are composed of these elements.…”
Section: Donaldson Personal Communication)supporting
confidence: 78%
“…EDS and SEM. Both electron dispersion spectroscopy (EDS) and scanning electron microscopy (SEM) of sandstone were done as previously described by Crocker et al (4). Three Berea cores (2-by 6-in.…”
Section: Donaldson Personal Communication)mentioning
confidence: 99%
See 1 more Smart Citation
“…This low value for the surface area suggests that the sample contained little clay. 3 For experiments using consolidated cores, Berea sandstone was cut into 1.5 in. diameter by 4 in.…”
Section: Methodsmentioning
confidence: 99%
“…Sumner and Mille (1996) presented many methods to determine the cation exchange capacity of a soil. Crocker et al (1983) presented the surface area (m 2 /g) and the cation exchange capacity for Bandera and Berea sandstone samples ( Table 9). The Bandera sandstone has higher CEC and surface area in comparison to Berea sandstone.…”
Section: Rock Characterizationmentioning
confidence: 99%