2002
DOI: 10.1016/s0024-3205(02)01627-2
|View full text |Cite
|
Sign up to set email alerts
|

Comparative study of human steroid 5α-reductase isoforms in prostate and female breast skin tissues: sensitivity to inhibition by finasteride and epristeride

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
7
0

Year Published

2006
2006
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 38 publications
(8 citation statements)
references
References 42 publications
1
7
0
Order By: Relevance
“…Figure 7 depicts the Stern-Volmer plot of fluorescence quenching of CQDs with different concentrations of quencher at four different temperatures i. e. 299, 304, 309, 314 K respectively. As per the reports, the plot F 0 / F versus concentration of quencher [Q] should be linear for the quenching type of static or dynamic [52]. The plot showing the good linearity within the investigated concentrations of quencher and agrees with Stern-Volmer equation.…”
Section: Fluorescence Quenching Mechanismsupporting
confidence: 74%
“…Figure 7 depicts the Stern-Volmer plot of fluorescence quenching of CQDs with different concentrations of quencher at four different temperatures i. e. 299, 304, 309, 314 K respectively. As per the reports, the plot F 0 / F versus concentration of quencher [Q] should be linear for the quenching type of static or dynamic [52]. The plot showing the good linearity within the investigated concentrations of quencher and agrees with Stern-Volmer equation.…”
Section: Fluorescence Quenching Mechanismsupporting
confidence: 74%
“…23,28,29 In certain concentrations, there is linear relationship between F 0 /F and [Pc] (Stern-Volmer curve) if the quenching type is single static or dynamic quenching. 30 The proposed maximum value for dynamic quenching process at room temperature is 2:0 Â 10 10 M À1 s À1 , 31 while k q in this study was found to be 10 13 M À1 s À1 . The results indicated that the°uorescence quenching of BSA and HSA by AlPc was a static quenching process.…”
Section: A±nity Measurementsmentioning
confidence: 47%
“…3(A) that for neutral pH, the nature of curve is linear within the studied concentration. This suggests that a single type of quenching, either static or dynamic quenching, exists at neutral pH [22]. But for the 3.5 and 9.5 pH the Stern-Volmer plots there is an upward curvature.…”
Section: Effect Of Phmentioning
confidence: 95%