2009
DOI: 10.1016/j.tripleo.2009.01.010
|View full text |Cite
|
Sign up to set email alerts
|

Comparative investigation of 2 rotary nickel-titanium instruments: protaper universal versus protaper

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
25
0
4

Year Published

2010
2010
2021
2021

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 21 publications
(32 citation statements)
references
References 27 publications
3
25
0
4
Order By: Relevance
“…Since PTU is a multi-file rotary system and SAF can irrigate and prepare at the same time, preparation time with PTU was longer than that of SAF. In some studies, the time was defined as only active filing time 33,35) ; however, the other study similar to ours added file changing and irrigation time to the active working time and found similar results with us 36) . In order to help the SAF file to reach working length with straight access, glide path preparation with #20 K file is recommended for 1.5 mm SAF instrument.…”
Section: Discussionsupporting
confidence: 80%
“…Since PTU is a multi-file rotary system and SAF can irrigate and prepare at the same time, preparation time with PTU was longer than that of SAF. In some studies, the time was defined as only active filing time 33,35) ; however, the other study similar to ours added file changing and irrigation time to the active working time and found similar results with us 36) . In order to help the SAF file to reach working length with straight access, glide path preparation with #20 K file is recommended for 1.5 mm SAF instrument.…”
Section: Discussionsupporting
confidence: 80%
“…The methodology applied in this study using two rotary systems revealed that RT Densell files have greater cutting capacity than K3 files, although other studies comparing manual preparation to rotary systems have reported no significant differences between the two systems [13,17]. It should be mentioned that the nickel-titanium RT Densell files, originally called NiTiTiee, were employed in this study because few previous scientific research studies have considered these tools, although they are product whose market price is very affordable.…”
Section: Discussionmentioning
confidence: 91%
“…Because the RT Densell files more easily stuck to the smooth surfaces of the canal, they will likely result in a greater threading effect, most likely fracture. Not only the angle of curvature and intensity of use but also the rotational speed, the fatigue of the instrument, the torque of the machine, the force applied by the operator, the type of movement used and, in particular, the design of the files are factors that increase the possibility of instrument fracture [1,9,13,16], which may eventually occur without warning [5]. A study using Profile, K3 and Race files concluded that K3 files had the greatest cycle fatigue resistance [17] and the greatest strain and fracture resistances [18].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Consequently, due to having an active tip of high flexibility and because it caused a great wear in the cervical and middle thirds as a result of multiple tapers, the system made preparation of the root canals safer and more effective. 5,6,7 The system was operated at 350 rpm with a torque of 3 N.…”
Section: Methodsmentioning
confidence: 99%