2013
DOI: 10.3311/ppch.2167
|View full text |Cite
|
Sign up to set email alerts
|

Comparative evaluation of microbial and chemical methods for assessing 4-chlorophenol biodegradation in soil

Abstract: Abbrevations 4-CP 4-chlorophenol UV-VIS ultraviolet-visible spectrophotometry GC-FID gas chromatometry with flame ionization detection GC-MS gas chromatometry with mass spectrometry REP GC randomly methylated beta-cyclodextrin extracted 4-CP content measured with GC-FID (Table 3) HEP GC hydroxypropyl beta-cyclodextrin extracted 4-CP content measured with GC-FID (Table 4) CP chlorophenol GN Gram-negative PCR-DGGE polymerase chain reaction and denaturing gradient gel electrophoresis PCP pentachlorophenol SIR sub… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
1
1

Relationship

2
6

Authors

Journals

citations
Cited by 15 publications
(10 citation statements)
references
References 31 publications
0
10
0
Order By: Relevance
“…The BIOLOG EcoPlate TM method was used to study the substrate utilization patterns of the soil microbial community. The measurement was carried out according to Nagy et al The metabolic fingerprints were analysed with DIALAB EL800 Microplate Reader and the average well colour development (AWCD = ∑( C‐ R )/31, where C is the absorbance value in the control cells and R is the absorbance value in each carbon source well) was calculated.…”
Section: Methodsmentioning
confidence: 99%
“…The BIOLOG EcoPlate TM method was used to study the substrate utilization patterns of the soil microbial community. The measurement was carried out according to Nagy et al The metabolic fingerprints were analysed with DIALAB EL800 Microplate Reader and the average well colour development (AWCD = ∑( C‐ R )/31, where C is the absorbance value in the control cells and R is the absorbance value in each carbon source well) was calculated.…”
Section: Methodsmentioning
confidence: 99%
“…Plates were incubated in the dark at 25 • C, and the absorbance of the wells was measured every 24 h for 120 h at 490 nm wavelength by DIALAB EL800 Microplate Reader. Although the Biolog EcoPlate™ method usually measures optical density (OD) at 590 nm, because the highest absorbance of the tetrazolium dye could be measured at this wavelength [31,34,36], our microplate reader was equipped with 405, 450, 490 and 630 nm filters, and the optimal OD values were provided at 490 nm [37,38].…”
Section: Biolog Ecoplate™mentioning
confidence: 99%
“…AWCD indicates the total metabolic capacity of sediment microbial communities in terms of carbon-source utilization. The OD values for data evaluation and comparisons were used at 120hr since these represented the optimal range of OD readings in our study (Gryta et al 2014;Nagy et al 2013).…”
Section: Community-level Physiological Pro Ling (Clpp)mentioning
confidence: 99%