2020
DOI: 10.11591/ijeecs.v18.i2.pp707-716
|View full text |Cite
|
Sign up to set email alerts
|

Comparative analysis of positive output super lift DC-DC luo converters

Abstract: <p>Due to the advancement in the semiconductor technologies, DC-DC converters are gaining the importance in several industrial applications. They form the core of the switched mode power supplies which are used in real time applications. The performance of the conventional converter is affected by the parasitic elements and their voltage gain is also limited. To improve upon this, Super lift converters converter were developed by Luo. Voltage lift technique increases the voltage in geometric progression … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
6
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 14 publications
0
6
0
Order By: Relevance
“…The output voltage of these linear regulators is lower than the input voltage. [10] Because to its commonalities, PV production has the most flexibility to be combined with EV charging stations of all renewable energy sources (RESs). [11] Yet, the inverter's extra capacity can be employed to offer grid-support services like reactive power production or quick flicker adjustment.…”
Section: Introductionmentioning
confidence: 99%
“…The output voltage of these linear regulators is lower than the input voltage. [10] Because to its commonalities, PV production has the most flexibility to be combined with EV charging stations of all renewable energy sources (RESs). [11] Yet, the inverter's extra capacity can be employed to offer grid-support services like reactive power production or quick flicker adjustment.…”
Section: Introductionmentioning
confidence: 99%
“…The PC for stepping-down converter is well addressed [17]. The broad analysis of various nonlinear controllers for LCs was addressed [18,19]. Though the output voltage of the LCs has spawned huge overshoots in load troubles, the detailed modeling of various DC-DC converters was deliberated [20].…”
Section: Introductionmentioning
confidence: 99%
“…FPOSLLC with classical Proportional Integral (PI) controller is discussed [8]. During the transient stage, the PI control for the same model exhibited huge overshoots in line/load changes and needed a long settling time of 0.038 s. e results of a wide-ranging examination of numerous factors for FPOSLLC are well described [9]. e converter was run in open-loop mode in this article.…”
Section: Introductionmentioning
confidence: 99%