2010
DOI: 10.1007/s00604-010-0520-0
|View full text |Cite
|
Sign up to set email alerts
|

Compact optical instrument for simultaneous determination of oxygen and carbon dioxide

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
15
0

Year Published

2011
2011
2019
2019

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 21 publications
(16 citation statements)
references
References 26 publications
1
15
0
Order By: Relevance
“…It exploits a secondary inner-filter effect of a long lifetime luminophore dye, platinum octaethylporphyrin, inmobilized on PVCD membranes, by a pH indicator, α-naphtholphthalein. It is implemented in a portable instrumentation with both optoelectronic components coated with sensing chemistry (LED with the luminophore and photodetector with the pH-active dye) [29], and later integrated into a multi-analyte platform for oxygen and CO2 [30]. Contributing factors from both the chemical layer fabrication process and the optical detection system have significant impact on the sensitivity and reproducibility of the sensing device.…”
mentioning
confidence: 99%
“…It exploits a secondary inner-filter effect of a long lifetime luminophore dye, platinum octaethylporphyrin, inmobilized on PVCD membranes, by a pH indicator, α-naphtholphthalein. It is implemented in a portable instrumentation with both optoelectronic components coated with sensing chemistry (LED with the luminophore and photodetector with the pH-active dye) [29], and later integrated into a multi-analyte platform for oxygen and CO2 [30]. Contributing factors from both the chemical layer fabrication process and the optical detection system have significant impact on the sensitivity and reproducibility of the sensing device.…”
mentioning
confidence: 99%
“…From this calibration curve, specifications such as the resolution and limit of detection (LOD) can be obtained. The resolution is calculated by taking derivatives on both sides of the equation and approximating these derivatives to increments [5] 2…”
Section: Figurementioning
confidence: 99%
“…The challenge now is to simplify the whole analysis system, avoiding the necessity for specialised training. Several studies can be found in the literature investigating alternatives to classic analytical methods, for instance, with the use of portable devices [2][3][4][5][6] or the novel usage of smartphones as detectors [7][8][9]. In this way, laboratory costs are reduced and there is no need for sample transportation.…”
Section: Introductionmentioning
confidence: 99%
“…The complexity increases further if more than on luminophore is present, and several parameters (e.g. [O 2 ], [CO 2 ], pH) have to be determined [5][6][7][8][9].…”
Section: Introductionmentioning
confidence: 99%