Compact Laser Doppler Choroidal Flowmeter

Abstract: A compact instrument is described that allows the measurement of the laser Doppler flow parameters, i.e., the velocity, the volume, and flow of blood in the foveal region of the human choroidal vascular system. This new device uses the optical principle of confocality for the delivery of the laser light to the site of measurement and heterodyne detection of the Doppler frequency shifted scattered light. Power of the incident light (785 nm) at the cornea is 90 μW. Measurements were obtained in both eyes of a gr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
58
0

Year Published

2002
2002
2012
2012

Publication Types

Select...
4
4
1

Relationship

0
9

Authors

Journals

citations
Cited by 52 publications
(58 citation statements)
references
References 7 publications
0
58
0
Order By: Relevance
“…Ray I s represents one of the scattering components with a deviation angle of θ 1 relative to the direction of the ray donated by I s , and a deviation angle of θ 2 relative to the direction of the z-axis. Doppler frequency shift achieved in ray I s corresponding to ray I i based on previous ray tracing is then given by [14][15][16] …”
Section: Theoretical Analysis 31 Ray Trace Modelmentioning
confidence: 99%
“…Ray I s represents one of the scattering components with a deviation angle of θ 1 relative to the direction of the ray donated by I s , and a deviation angle of θ 2 relative to the direction of the z-axis. Doppler frequency shift achieved in ray I s corresponding to ray I i based on previous ray tracing is then given by [14][15][16] …”
Section: Theoretical Analysis 31 Ray Trace Modelmentioning
confidence: 99%
“…In our study, a compact laser Doppler flowmeter, which has been described in detail previously, 33,34 was used for the ChBF measurements. Measurements were performed in the fovea by asking the subject to fixate directly at the beam.…”
Section: Measurementsmentioning
confidence: 99%
“…12 The sensitivity of the LDF measurements in AMD eyes of this study was consistent with that described in healthy eyes using the same device. 7,13,14 The calculation of the sensitivity is bound to an experience and not to the instrument. It gives the minimum variation of a parameter that is statistically significant in response to a given stimulus (PDT in this experiment) for a given population of patients.…”
Section: Discussionmentioning
confidence: 99%
“…Subfoveal blood flow after photodynamic therapy V Vinh Moreau-Gaudry et al elsewhere, 7 and we give here only a brief summary. It is based on the fact that reflected light on moving red blood cells (RBCs) will shift in frequency (Doppler effect).…”
Section: Choroidal Blood Flowmentioning
confidence: 99%