2019
DOI: 10.3390/s19184039
|View full text |Cite
|
Sign up to set email alerts
|

Commercial Screen-Printed Electrodes Based on Carbon Nanomaterials for a Fast and Cost-Effective Voltammetric Determination of Paracetamol, Ibuprofen and Caffeine in Water Samples

Abstract: Carbon screen-printed electrode (SPCE), multi-walled carbon nanotubes modified screen-printed electrode (SPCNTE), carbon nanofibers modified screen-printed electrode (SPCNFE), and graphene modified screen-printed electrode (SPGPHE) were in a pioneer way tested as sensors for the simultaneous determination of the two most consumed pain-killers, paracetamol (PA) and ibuprofen (IB), and the stimulant caffeine (CF) in water by differential pulse voltammetry (DPV). Their analytical performances were compared, and t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
33
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 47 publications
(36 citation statements)
references
References 28 publications
(47 reference statements)
3
33
0
Order By: Relevance
“…Conversely, for tetracycline, the CB sensor (GCE/CB-PS [ 137 ]) outperformed compared with graphene (GCE/graphene/L-cysteine [ 74 ]) and MWCNT (GCE/MWCNT-Nafion ® [ 120 ]), which obtained exactly the same LOD value (0.12 μmol L −1 ) whereas for trimethoprim the CB sensor (GCE/CB-CuPh [ 138 ]) presented also higher value of LOD (about 20-times higher) compared with the MWCNT (CPE(MWCNT-SbNPs) [ 124 ]). In turn, LOD of sensors for acetaminophen based on graphene (GCE/graphene-PDDA [ 82 ]), MWCNT [CPE(MWCNT) [ 110 ] and GCE/MWCNT-CONH-TAPP/AuNPs [ 111 ]) and CNF (SPCNFE [ 151 ]) are in line with each other, except for Au/MWCNT-CuNPs [ 109 ] that achieved an approximately 10-fold lower value, while in both CB sensors (GCE/AgNPs-CB/PEDOT:PSS [ 141 ] and SPE/CB(BP) [ 140 ]) values vary widely by 2 orders of magnitude. By analyzing the data, we can conclude therefore that there is not a clear tendency for the impact of the type of carbon nanomaterial in the reached sensitivity.…”
Section: Overall Comparison Between Reported Nanostructured Carbonmentioning
confidence: 99%
See 1 more Smart Citation
“…Conversely, for tetracycline, the CB sensor (GCE/CB-PS [ 137 ]) outperformed compared with graphene (GCE/graphene/L-cysteine [ 74 ]) and MWCNT (GCE/MWCNT-Nafion ® [ 120 ]), which obtained exactly the same LOD value (0.12 μmol L −1 ) whereas for trimethoprim the CB sensor (GCE/CB-CuPh [ 138 ]) presented also higher value of LOD (about 20-times higher) compared with the MWCNT (CPE(MWCNT-SbNPs) [ 124 ]). In turn, LOD of sensors for acetaminophen based on graphene (GCE/graphene-PDDA [ 82 ]), MWCNT [CPE(MWCNT) [ 110 ] and GCE/MWCNT-CONH-TAPP/AuNPs [ 111 ]) and CNF (SPCNFE [ 151 ]) are in line with each other, except for Au/MWCNT-CuNPs [ 109 ] that achieved an approximately 10-fold lower value, while in both CB sensors (GCE/AgNPs-CB/PEDOT:PSS [ 141 ] and SPE/CB(BP) [ 140 ]) values vary widely by 2 orders of magnitude. By analyzing the data, we can conclude therefore that there is not a clear tendency for the impact of the type of carbon nanomaterial in the reached sensitivity.…”
Section: Overall Comparison Between Reported Nanostructured Carbonmentioning
confidence: 99%
“…Despite its robustness and reliability, this conventional electrode is more suitable for laboratorial work rather for in-situ environmental applications due to its bulkier dimensions. In this sense, screen-printed electrodes [ 72 , 73 , 89 , 90 , 140 , 151 ] and the film type electrodes of gold [ 109 ] and FTO [ 83 ] present high area-to-volume ratio enabling miniaturization and portability and, therefore, are more convenient for in loco analysis. In this miniaturization process, carbon nanomaterials can be extremely useful and exceptionally reliable through the production, for example, of buckypaper type electrodes.…”
Section: Overall Comparison Between Reported Nanostructured Carbonmentioning
confidence: 99%
“…Very recently, we have developed and applied successful methodologies for the determination of organic UV filters [33] and pharmaceuticals [34] in water by using SPEs.…”
Section: Reagentsmentioning
confidence: 99%
“…Screen-printed devices have found promising applications in the environmental analysis because of their suitability for on-site analysis, supported by their linear output, low power requirement, quick response, high sensitivity, and capability to operate at room temperature [32]. Very recently, we have developed and applied successful methodologies for the determination of organic UV filters [33] and pharmaceuticals [34] in water by using SPEs.…”
Section: Introductionmentioning
confidence: 99%
“…A number of analytical techniques were used for AC determination, such as UV spectrophotometry [30], reverse-phase high-performance liquid chromatography [31], high-performance thin-layer chromatography [32], liquid chromatography-tandem mass spectrometry [33], thin-layer chromatography [34], and capillary electrophoresis [35]. Electrochemical techniques, which are characterized by the cheapness, ease and speed of the analysis, were also used for AC determination using many types of carbon electrodes including carbon paste electrodes [36][37][38][39][40], glassy carbon electrode [41,42] or screen-printed carbon electrodes [43,44]. Acetaminophen is also often used in electrochemical analysis to compare analytical performance of the developed sensors [45][46][47][48] as its electrochemical properties have been thoroughly examined.…”
mentioning