Combining Central and Peripheral Videokeratoscope Maps to Investigate Total Corneal Topography

Abstract: The topography of the entire cornea can be represented by combining multiple measurements from a Placido videokeratoscope. Conic fits based on central topography data are a poor representation of the total corneal shape.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
23
0
2

Year Published

2006
2006
2020
2020

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 19 publications
(28 citation statements)
references
References 16 publications
2
23
0
2
Order By: Relevance
“…In that case, the mean dimension of 21 combined maps is 11.45 mm (standard deviation: 0.29 mm) horizontally and 11.33 mm (standard deviation: 0.40 mm) vertically. This result is comparable with the results reported by Franklin et al 6 One combined map for this example is displayed in Figure 7 having an increase in area of approximately 65% compared to the original central map.…”
Section: Resultssupporting
confidence: 93%
See 1 more Smart Citation
“…In that case, the mean dimension of 21 combined maps is 11.45 mm (standard deviation: 0.29 mm) horizontally and 11.33 mm (standard deviation: 0.40 mm) vertically. This result is comparable with the results reported by Franklin et al 6 One combined map for this example is displayed in Figure 7 having an increase in area of approximately 65% compared to the original central map.…”
Section: Resultssupporting
confidence: 93%
“…These maps are generated based on the same conic surface in Franklin et al 6 (radius r 0 = 7:2 mm, asphericity Q = À 0:51). To prevent the test set from being rotationally symmetric, the conic surfaces produced have been elongated in the X-direction by a factor of ffiffiffiffiffiffiffiffiffi 1:05 p .…”
Section: Data Setsmentioning
confidence: 99%
“…Current Placido-based topography systems are limited in their ability to capture the corneal surface to a diameter of about 9 mm horizontally and 7.5 mm vertically. By developing a software algorithm that allowed capture of central and peripheral corneal topography, Franklin et al 36 were successful in representing an average of 11.3 mm of the cornea horizontally and 10.3 mm vertically. However, the procedure was tedious and computationally intensive.…”
Section: Figure 13mentioning
confidence: 99%
“…To illustrate the effectiveness of the proposed generalised conic function we consider data of an extended corneal surface recently reported by Franklin et al. (2006).…”
Section: Fitting Generalised Conicsmentioning
confidence: 99%