2009
DOI: 10.1002/cphc.200900049
|View full text |Cite
|
Sign up to set email alerts
|

Combined Online Spectroscopic, Calorimetric, and Chemometric Analysis: Reaction Enthalpy Determinations in Single and Parallel Reactions

Abstract: Calorimetry and signal processing: Vibrational spectroscopies, heat-flow microcalorimetry, and multivariate analysis are combined to decouple the reaction enthalpies of parallel reactions [picture: see text]. This methodology allows the evaluation of reaction enthalpy from complex systems without recourse to conventional kinetic modeling. Simultaneous in situ/online spectroscopy and heat-flow measurements as well as multivariate analyses are performed, apparently for the first time, to determine heats of react… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
7
0
1

Year Published

2009
2009
2016
2016

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(9 citation statements)
references
References 41 publications
1
7
0
1
Order By: Relevance
“…These values are also compared to those previously and independently determined using FTIR spectroscopy as well as calorimetric measurements. 8,10 The results show that the rate constants determined from the present refractive index method are in good agreement with those determined from other techniques. It is also noted, however, that the standard deviations of the rate constants determined from the present refractive index measurements are typically greater than those determined from both spectroscopic and calorimetric measurements.…”
Section: Resultssupporting
confidence: 82%
See 3 more Smart Citations
“…These values are also compared to those previously and independently determined using FTIR spectroscopy as well as calorimetric measurements. 8,10 The results show that the rate constants determined from the present refractive index method are in good agreement with those determined from other techniques. It is also noted, however, that the standard deviations of the rate constants determined from the present refractive index measurements are typically greater than those determined from both spectroscopic and calorimetric measurements.…”
Section: Resultssupporting
confidence: 82%
“… a Standard deviations are reported as 2σ. b Evaluated directly from concentration data (obtained using FTIR spectroscopy) as reported in ref . c Evaluated directly from heat flow data (obtained using flow-through Thermal Activity Monitor (TAM) III microcalorimeter) as reported in ref . d Reference . e Independently measured using TAM III microcalorimeter with ampoule measurements. Detailed procedure can be found in ref . …”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Estos iones provocan la rotura de los enlaces és-ter, tanto de la oleuropeína (que es el objetivo del tratamiento) como de los polisacáridos estructurales (pectina, hemicelulosa y celulosa) (Marsilio et al, 1996). La hidrólisis alcalina de un éster libera calor, es exotérmica (Schneider y Stoessel, 2005;Tjahjono et al, 2009;Taylor y Kluger, 1992;Wadsö, 1958), de modo que las reacciones que se producen dentro de la aceituna generan calor y pueden ser responsables, junto con la transferencia de calor de las aceitunas a la solución y con la dilución de la concentración de sosa, del aumento de temperatura progresivo durante la etapa de cocido.…”
Section: Agradecimientosunclassified