2016
DOI: 10.1016/j.microc.2015.07.019
|View full text |Cite
|
Sign up to set email alerts
|

Combination of knotted reactor with portable tungsten coil electrothermal atomic absorption spectrometer for on-line determination of trace cadmium

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 12 publications
(4 citation statements)
references
References 22 publications
0
4
0
Order By: Relevance
“…KRs allow high flow rates with lowpressure drops (the reactor is an open tube); they prevent loss of sensitivity due to dispersion; they are free from contamination since they are made of inert material (PTFE); KR is easy to build and inexpensive with long lifetime without efficiency losing. 16,17 New ideas involving the use of KRs include, as example, three-dimensional printed knotted reactors for sensitive differentiation of silver nanoparticles and ions in aqueous environmental samples, 18 a tandem of KR coupled with a portable tungsten coil electrothermal atomic absorption spectrometer for online determination of trace cadmium, 19 KR modification with activated carbon for determination of arsenic species in medicinal herbs and tea infusions, 20 and an association of cloud-point extraction with KR for cobalt preconcentration following by ET AAS (electrothermal AAS) determination in drinking water. 21 Multicommutation is an automation strategy applied to continuous-flow analysis systems, with configurations modified by computer-controlled commutators.…”
Section: Use Of Arduino In the Development Of A New And Fast Automatementioning
confidence: 99%
“…KRs allow high flow rates with lowpressure drops (the reactor is an open tube); they prevent loss of sensitivity due to dispersion; they are free from contamination since they are made of inert material (PTFE); KR is easy to build and inexpensive with long lifetime without efficiency losing. 16,17 New ideas involving the use of KRs include, as example, three-dimensional printed knotted reactors for sensitive differentiation of silver nanoparticles and ions in aqueous environmental samples, 18 a tandem of KR coupled with a portable tungsten coil electrothermal atomic absorption spectrometer for online determination of trace cadmium, 19 KR modification with activated carbon for determination of arsenic species in medicinal herbs and tea infusions, 20 and an association of cloud-point extraction with KR for cobalt preconcentration following by ET AAS (electrothermal AAS) determination in drinking water. 21 Multicommutation is an automation strategy applied to continuous-flow analysis systems, with configurations modified by computer-controlled commutators.…”
Section: Use Of Arduino In the Development Of A New And Fast Automatementioning
confidence: 99%
“…Some novel detection methods have been developed for the onsite quantitative analysis of HMs in the last few years. Wen et al established a portable tungsten coil electrothermal atomic absorption spectrometer for HM field analysis [ 14 , 15 , 16 ]. Wang et al designed and implemented a field-based HM detection system involving electrochemical differential pulse anodic stripping voltammetry [ 17 ].…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, the development of a highly sensitive silver ion recognition receptor and a reliable detection method is of great significance for human health and food safety. At present, the detection of silver ions is usually limited to traditional analytical methods, including atomic absorption spectroscopy (AAS) [13,14], atomic emission spectroscopy (AES) [15,16], inductively coupled plasma mass spectrometry (ICP-MS) and the ion selective electrode method (ISE) [17][18][19][20]. However, these methods not only rely on expensive large-scale precision instruments, cumbersome pretreatment and skilled professional technicians, but they also have time-consuming operation steps, seriously affecting the efficiency of routine and on-site detection.…”
Section: Introductionmentioning
confidence: 99%