2021
DOI: 10.1021/acs.analchem.1c03946
|View full text |Cite
|
Sign up to set email alerts
|

Collision-Induced Unfolding Reveals Stability Differences in Infliximab Therapeutics under Native and Heat Stress Conditions

Abstract: Ion mobility-mass spectrometry (IM-MS) and collision-induced unfolding (CIU) assays of monoclonal antibody (mAb)-based biotherapeutics have proven sensitive to disulfide bridge structures, glycosylation patterns, and small molecule conjugation levels. Despite promising prior reports detailing the capabilities of IM-MS and CIU to differentiate biosimilars, generic mAb therapeutics, there remain questions surrounding the sensitivity of CIU to mAb structure changes that occur upon stress, the reproducibility of s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
21
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 23 publications
(21 citation statements)
references
References 48 publications
0
21
0
Order By: Relevance
“…CIU has long been proposed as an ideal approach for inclusion in biotherapeutic pipelines, with a substantial body of work supporting its ability to characterize relevant mAb structures. 12,14,15,46,52,53 A high level of technical reproducibility is required to conduct comparative analyses across mAb subtypes. Although the BSA results discussed above can be used to positively project the reproducibility of CIU experiments for protein-based pharmaceuticals, mAbs are over two times larger (∼150 kDa), and thus pose unique challenges for high-precision IM-MS and CIU.…”
Section: Evaluation Of Production-grade Hardwarementioning
confidence: 99%
See 1 more Smart Citation
“…CIU has long been proposed as an ideal approach for inclusion in biotherapeutic pipelines, with a substantial body of work supporting its ability to characterize relevant mAb structures. 12,14,15,46,52,53 A high level of technical reproducibility is required to conduct comparative analyses across mAb subtypes. Although the BSA results discussed above can be used to positively project the reproducibility of CIU experiments for protein-based pharmaceuticals, mAbs are over two times larger (∼150 kDa), and thus pose unique challenges for high-precision IM-MS and CIU.…”
Section: Evaluation Of Production-grade Hardwarementioning
confidence: 99%
“…To date, our work has demonstrated the ability of this IM-MS platform to produce CIU data similar to those reported previously. 9,15,45,46 In this study, we evaluated the reproducibility of CIU fingerprints on three geographically distinct DTIM-MS instruments equipped with prototype high-energy source hardware of the same design. Furthermore, we improved upon previously described methods, achieving higher-energy CIU of large proteins and protein complexes using a standard ESI source without the requisite addition of heavier dopant gases (i.e.…”
mentioning
confidence: 99%
“…Regarding conformational isomers, IM-MS and collision-induced unfolding (CIU) analyses have been shown to be sensitive to disulfide bond structure, glycosylation patterns, and small-molecule binding levels. , Wei et al can quickly determine the type of isomer by electronic excitation dissociation and TIMS to avoid mistaking conformers for isomers. Recently, Panczyk et al analyzed the structure of protein complexes by TIMS and SID.…”
Section: Applications Of Im-ms For the Separation And Characterizatio...mentioning
confidence: 99%
“…CIU has long been proposed as an ideal approach for inclusion in biotherapeutic pipelines, with a substantial body of work supporting its ability to characterize relevant mAb structures. 12,14,15,46,52,53 A high level of technical reproducibility is required to conduct comparative analyses across mAb subtypes. Although the BSA results discussed above can be used to positively project the reproducibility of such CIU experiments for protein-based pharmaceuticals, mAbs are over two times larger (~150 kDa), and thus pose unique challenges for high-precision IM-MS and CIU.…”
Section: Immunoglobulin G1 (Igg1)mentioning
confidence: 99%
“…To date, our work has demonstrated the ability of this IM-MS platform to produce CIU data similar to those reported previously. 9,15,45,46 In this study, we present the reproducibility of CIU fingerprints on three geographically distinct DTIM-MS instruments each equipped with prototype highenergy source hardware of the same design. Furthermore, we improved upon previously described methods, achieving higher-energy CIU of large proteins and protein complexes using a standard ESI source without the requisite addition of heavier dopant gases (i.e.…”
mentioning
confidence: 99%