2012
DOI: 10.1109/tsg.2011.2178080
|View full text |Cite
|
Sign up to set email alerts
|

Co-Optimal Placement of Measurement Devices and Their Related Communication Infrastructure in Wide Area Measurement Systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
71
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 78 publications
(71 citation statements)
references
References 17 publications
0
71
0
Order By: Relevance
“…A relevant work addressing the problem of distribution system state estimation was proposed [15] to minimize the state estimation errors. The optimal PMU placement and its communication infrastructure was designed [16] to address the problem of state estimation. A procedure finding the optimal trade-offs between PMUs and metering devices for distribution state estimation was investigated in [17].…”
Section: Related Workmentioning
confidence: 99%
“…A relevant work addressing the problem of distribution system state estimation was proposed [15] to minimize the state estimation errors. The optimal PMU placement and its communication infrastructure was designed [16] to address the problem of state estimation. A procedure finding the optimal trade-offs between PMUs and metering devices for distribution state estimation was investigated in [17].…”
Section: Related Workmentioning
confidence: 99%
“…Second, the system's admittance matrix is used to calculate the system's connectivity matrix. In this regard, it is pivotal to have the total length of transmission lines for the selected test system which is assumed to be 1134 kilometers [8].…”
Section: A 17 Bus Test Systemmentioning
confidence: 99%
“…As shown in Table II, the best architectural design is introduced in terms of the OPGW coverage for suggested control center bus. It should be noted that OPGW coverage as an optimization parameter is firstly introduced in [8] and is equal to ratio of length of employed OPGW to total length of transmission lines in the selected test system. In the same table, CI Links shows the best selected routes for both methodologies to connect control center to PMU buses.…”
Section: A 17 Bus Test Systemmentioning
confidence: 99%
See 1 more Smart Citation
“…Liu et al [1] aimed at optimizing meter placement for an active distribution grid, which uses heterogeneous measurements provided by phasor measurement units (PMUs), smart metering systems, and traditional distribution grid measurements. Shahraeini et al [2] tried to optimize meters placement and communication infrastructure simultaneously, to improve observability of the whole monitoring system and reduce the total cost.…”
Section: Introductionmentioning
confidence: 99%