2005
DOI: 10.1016/j.talanta.2004.07.018
|View full text |Cite
|
Sign up to set email alerts
|

Cloud point extraction of iron(III) and vanadium(V) using 8-quinolinol derivatives and Triton X-100 and determination of 10moldm level iron(III) in riverine water reference by a graphite furnace atomic absorption spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
49
1
2

Year Published

2007
2007
2020
2020

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 164 publications
(56 citation statements)
references
References 15 publications
2
49
1
2
Order By: Relevance
“…The preconcentration factor obtained was of 83 fold resulted in achieving the limit of detection (LOD) of 3.42 ngmL -1 ( Table 2). Concerning LOD, our findings was 5 fold more better than obtained by Giokas et al, 31 who used CPE-FI-AAS , but about 2 fold less than those obtained by Ohashi et al, 32 and Shakerian et al, 33 whom used CPE-GFAAS and CPE-FI-AAS. The molar absorptivities, Sandell's sensitivities, extraction efficiencies for NOR and Fe(III) were also given in Tables 1 and 2, indicative the proposed method has a good sensitivity and extractability.…”
Section: Calibration Graphs For Nor Drug and Iron(iii) Ionscontrasting
confidence: 65%
“…The preconcentration factor obtained was of 83 fold resulted in achieving the limit of detection (LOD) of 3.42 ngmL -1 ( Table 2). Concerning LOD, our findings was 5 fold more better than obtained by Giokas et al, 31 who used CPE-FI-AAS , but about 2 fold less than those obtained by Ohashi et al, 32 and Shakerian et al, 33 whom used CPE-GFAAS and CPE-FI-AAS. The molar absorptivities, Sandell's sensitivities, extraction efficiencies for NOR and Fe(III) were also given in Tables 1 and 2, indicative the proposed method has a good sensitivity and extractability.…”
Section: Calibration Graphs For Nor Drug and Iron(iii) Ionscontrasting
confidence: 65%
“…Cu (Kulichenko et al, 2003), Mn ( Doroschuk et al, 2004), Co (Nascentes & Arruda, 2003), Cd and Ni (Manzoori & Karim-Nezhad, 2004), Ag and Au (Mesguita da Silva et al, 1998) were determined by FAAS. CPE was also applied for extraction of Fe(III) (Ohashi et al, 2005) and As(III) and As(V) (Shemirani et al, 2005) before determination by ET-AAS. Cd, Cu, Pb, and Zn (Chen & Teo, 2001) were simultaneous extracted as complex with 1-(2-thiazolylazo)-2-naphthol (TAN) using TritonX-114 prior to determination by FAAS.…”
Section: Applications Of Cpe In Atomic Absorption Spectrometrymentioning
confidence: 99%
“…In CPE with a simple single-step extraction procedure analysis of many samples enable researchers to perform the overall procedure easily on-line [14][15][16][17][18][19][20][21][22][23][24][25][26][27].…”
Section: Introductionmentioning
confidence: 99%