2013
DOI: 10.1016/j.egypro.2013.06.765
|View full text |Cite
|
Sign up to set email alerts
|

Closed Loop Speed Control of Induction Generator with Scalar-control Inverters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
5
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 14 publications
0
5
0
Order By: Relevance
“…It follows that the stray loss depends on the square of the rotor current and the machine's full load slip. From the proposed equivalent circuit, the load resistance Ŕ ́(1 − 𝑠) ∕ 𝑠 𝑟 is derived as (7).…”
Section: Stray Load Loss Resistance Modelmentioning
confidence: 99%
See 1 more Smart Citation
“…It follows that the stray loss depends on the square of the rotor current and the machine's full load slip. From the proposed equivalent circuit, the load resistance Ŕ ́(1 − 𝑠) ∕ 𝑠 𝑟 is derived as (7).…”
Section: Stray Load Loss Resistance Modelmentioning
confidence: 99%
“…Various dynamic models of SEIG analysis have been presented by researchers [1]- [7]. In all of these models, the cross-coupling saturation of magnetizing inductance, the dynamic saturation of leakage inductances, the influence of magnetic saturation on the iron core, friction, and windage resistance, and the stray load loss resistance are neglected, which leads to un-accurate results of those models.…”
Section: Introductionmentioning
confidence: 99%
“…is highly useful in mediumand high-speed TIM because of its simple implementation in hardware [12]. The operating principle of the V/f control involves keeping a constant ratio between peak phase voltage and frequency to maintain a constant magnetic flux in the air gap.…”
Section: Design Of the Fuzzy Speed Controllermentioning
confidence: 99%
“…, where is the DC voltage source of the inverter [14]. SVPWM switching time shares are calculated based on the location inside any sector as follows [12].…”
mentioning
confidence: 99%
“…The non-conventional energy sources are going to be depleted increasingly day by day, based on a survey the oil will be reach low level in about 40 years and the coal reserves will be depleted in about 120 years. Therefore, the new millennium belongs to renewable energy sources [1][2][3][4][5][6]. Sometimes in rural and remote areas, where it is difficult to install the transmission and distribution line, for such an areas SEIG is found to be suitable for power generation from such renewable energy sources due to its inherent advantages [7] such as low cost, simple construction, little maintenance, absence of dc source, brushless etc compared to conventional generator.…”
Section: Introductionmentioning
confidence: 99%