Abstract: A new disposable bleeding time device (Hemalet) was tested in 20 normal individuals and 11 patients with various bleeding disorders. The results were compared with those of Simplate II. The mean bleeding time for normal individuals was 5.4 +/- 1.5 (mean +/- 1 SD) minutes by Hemalet and 5.8 +/- 1.4 (mean +/- 1 SD) minutes by Simplate II, with good correlation between the results by the two devices (r = 0.81). The bleeding time in patients with various bleeding disorders were also comparably prolonged between th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

1988
1988
2006
2006

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…Platelets were also counted with a hemocytometer by optical microscopy. The bleeding time was measured with a fully automated incision-making device (Surgicutt, International Technidyne Corporation, Edison, NJ) using a modified Ivy method (14). In vitro platelet aggregation was studied in citrated platelet-rich plasma (PRP) by the method of Born as previously reported (15).…”
Section: Basic Hematological Analysismentioning
confidence: 99%
“…Platelets were also counted with a hemocytometer by optical microscopy. The bleeding time was measured with a fully automated incision-making device (Surgicutt, International Technidyne Corporation, Edison, NJ) using a modified Ivy method (14). In vitro platelet aggregation was studied in citrated platelet-rich plasma (PRP) by the method of Born as previously reported (15).…”
Section: Basic Hematological Analysismentioning
confidence: 99%
“…Bleeding time wasmeasured with afullyautomated incisionmaking device (Surgicutt, InternationalT echnidyneC orporation, Edison,USA)according to amodified Ivy method (11). In vitro plateleta ggregation wass tudiedi nc itrated platelet-rich plasma usingthe Bornmethodaspreviouslyreported (12).Plateleta gonistsw ere fibrillar collagent ype I, 4a nd 20 µ g/ml (Chrono-LogC orporation, Havertown, USA), ADP 5a nd 20 mM and ristocetin 0.7 and 1.5 mg/ml(both from Sigma Chemi-calCo, St.Louis, USA).…”
Section: Basichematological Analysesmentioning
confidence: 99%
“…The bleeding time was measured by the method of Mielke et al (4), with a modification using Simplate template II device (General Diagnos tics, Morris Plains, NJ) and making two 5 mm horizontal incisions on the (5). Blood samples were collected by venipuncture through a 21 gauge butterfly needle.…”
Section: A S S a Y M E Th O D Smentioning
confidence: 99%