2018
DOI: 10.1016/j.jebdp.2017.07.007
|View full text |Cite
|
Sign up to set email alerts
|

Clinical Factors Affecting the Accuracy of Guided Implant Surgery—A Systematic Review and Meta-analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
119
4
8

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 153 publications
(161 citation statements)
references
References 38 publications
4
119
4
8
Order By: Relevance
“…While the accuracy between the planned and placed implants inserted by the static surgical stents was extensively studied (Tahmaseb, Wismeijer, Coucke, & Derksen, 2014;Zhou, Liu, Song, Kuo, & Shafer, 2018), such studies are limited for the dynamic navigation system. Most of these studies are confined to arbitrary case series without a valid control (Guo et al, 2018).…”
Section: Discussionmentioning
confidence: 99%
“…While the accuracy between the planned and placed implants inserted by the static surgical stents was extensively studied (Tahmaseb, Wismeijer, Coucke, & Derksen, 2014;Zhou, Liu, Song, Kuo, & Shafer, 2018), such studies are limited for the dynamic navigation system. Most of these studies are confined to arbitrary case series without a valid control (Guo et al, 2018).…”
Section: Discussionmentioning
confidence: 99%
“…The accuracy of sCAIS is defined as the deviation between the planned and the actual position of an implant . This deviation can be a result of multiple sources: from the imaging process, data transfer, template manufacture, inaccurate positioning of the guide in the mouth, and drill errors . These variables may influence the angulation, length, and diameter of the osteotomy as well as implant insertion that translates to deviations in implant position …”
Section: Introductionmentioning
confidence: 99%
“…The accuracy of the sCAIS can be affected by several factors, including guide position, fixation, guide type, production method, flap approach, and method of implant insertion (Bover-Ramos, Vina-Almunia, Cervera-Ballester, Penarrocha-Diago, & Garcia-Mira, 2018;Jung et al, 2009;Pozzi et al, 2016;Raico Gallardo et al, 2017;Schneider et al, 2009;Tahmaseb et al, 2014;Van Assche et al, 2012;Zhou, Liu, Song, Kuo, & Shafer, 2018). Studies further highlighted the importance of guide fixation and stabilization as it has been shown that mobility of the surgical guide, during the implant bed preparation, can be responsible for high deviation values in the final implant position (Di Giacomo, Cury, Araujo, Sendyk, & Sendyk, 2005;Jung et al, 2009).…”
mentioning
confidence: 99%