Clinical evaluation of multiparameter correction equations for Goldmann applanation tonometry

Abstract: Purpose To evaluate and compare the multiparameter equations in correcting intraocular pressure (IOP) measurements obtained using the Goldmann applanation tonometer (IOPG) for the effects of central corneal thickness (CCT), corneal curvature (R), and age in different ethnic populations. Methods Data of IOPG, CCT, R, and age were collected from three clinical centers. The sample size consisted of 945 eyes of 945 glaucoma patients or suspects (669 Europeans, 127 African Americans, and 149 Indians). The 'correcte… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
11
0

Year Published

2015
2015
2020
2020

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(15 citation statements)
references
References 35 publications
0
11
0
Order By: Relevance
“…IOP measured with different methods, a multivariate analysis was conducted 9 . The findings presented in Table 3 (Table 3).…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…IOP measured with different methods, a multivariate analysis was conducted 9 . The findings presented in Table 3 (Table 3).…”
Section: Resultsmentioning
confidence: 99%
“…11 The effect of other parameters that influence GAT have been investigated more recently (age, axial length and biomechanical parameters). 8,9,12,13 Nevertheless, none of these attempts have yielded a universally accepted correction formula. 7,9,13 The consequence of this is that there are several correction methods available rendering it difficult to make a comparative analysis between different studies.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…37 It was developed using numerical, finite element simulations of the Corvis ST procedure applied on human eye models with different tomographies (including thickness profiles), ages, and IOP values. 8,35,[38][39][40] The analysis was used to provide bIOP, which are IOP estimates significantly less affected by corneal parameters and given as a function of measured IOP, CCT, and age. The bIOP formula used was a modified algorithm of the published formula 37 :…”
Section: Iop Measurementmentioning
confidence: 99%
“…6,13 In response, a number of multiparameter correction equations 10 were developed to mitigate errors induced by CCT, central corneal radius of curvature (R), and age on GAT-IOP, and these equations were successful to different extents in reducing the association of IOP measurements with the cornea's stiffness parameters. [14][15][16] As a further response to the problems reported in GAT with the stiffness-related inaccuracies, the dynamic contour tonometer (DCT) was developed by SMT Swiss Microtechnology AG, Switzerland, on the basis of the principle of contour matching (Fig. 1A).…”
mentioning
confidence: 99%