2009
DOI: 10.1111/j.1475-1313.2009.00634.x
|View full text |Cite
|
Sign up to set email alerts
|

Clinical assessment of the lower tear meniscus height

Abstract: Careful instillation of fluorescein does not affect normal TMH values. Fluorescein is washed out from the lower tear meniscus 5 min after instillation. Higher values of the TMH can be found at nasal and temporal locations compared to the center of the lower eye lid.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
31
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 34 publications
(37 citation statements)
references
References 48 publications
1
31
0
Order By: Relevance
“…However, we used the corneal wavefront guided ablation profiles, which have the same origins (topographic measurement) as topography-guided treatments but base upon the optical effects of the topography of the cornea instead of the elevation values of the cornea. We have reported refractive stability and optical benefits using the wavefront guided profiles in normal refractive procedures 19 and therapeutic procedures13, 26 in the past. Furthermore, the calculation of corneal asphericity as a 3-D fit renders more accurate results when it is based on the corneal wavefront aberrations rather than on the corneal topography of the principal meridians 27 .…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, we used the corneal wavefront guided ablation profiles, which have the same origins (topographic measurement) as topography-guided treatments but base upon the optical effects of the topography of the cornea instead of the elevation values of the cornea. We have reported refractive stability and optical benefits using the wavefront guided profiles in normal refractive procedures 19 and therapeutic procedures13, 26 in the past. Furthermore, the calculation of corneal asphericity as a 3-D fit renders more accurate results when it is based on the corneal wavefront aberrations rather than on the corneal topography of the principal meridians 27 .…”
Section: Discussionmentioning
confidence: 99%
“…All the patients were treated with corneal wavefront-guided ablation profiles 18 calculated using the ORK-CAM software module 19 (SCHWIND eye-tech-solutions). A defined epithelial thickness profile 20 (55 μm in the centre and 65 μm at 4 mm radial distance) was ablated without using any masking fluid.…”
Section: Methodsmentioning
confidence: 99%
“…50,54 All statistical tests were performed using the software package SPSS v. 19.0 for Windows (SPSS Inc, Chicago, IL). & Subjects stratified by age: 25 years or younger (n = 88), 25 to 45 years (n = 67), and 45 years or older (n = 22).…”
Section: Discussionmentioning
confidence: 99%
“…The TM was measured according to defined criteria 19,34 in its central portion (at 6 o'clock) as the distance between the darker edge of the lower eyelid and the upper limit of the TM using ImageJ. The TMH was marked using the straight tool, which allows the user to draw a line (Fig.…”
Section: Objective Measurement Of Tmhmentioning
confidence: 99%
See 1 more Smart Citation