2005
DOI: 10.1536/ihj.46.1123
|View full text |Cite
|
Sign up to set email alerts
|

Clinical and Hemodynamic Follow-up of a Patient After Operation for Dissection of an Ascending Aortic Aneurysm Secondary to Coarctation of the Aorta

Abstract: SUMMARYWe present clinical follow-up of a 20-year-old male with an aortic aneurysm secondary to aortic coarctation. The diagnosis of aortic aneurysm secondary to aortic coarctation was made in 1997. The patient did not agree to undergo any invasive or therapeutic procedures at that time. He presented to an emergency unit with severe chest pain after chest trauma obtained during judo exercises in 1998. Two-dimensional echocardiography showed bicuspid aortic valves, an ascending aortic aneurysm 6 cm in diameter … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
6
0

Year Published

2011
2011
2018
2018

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 14 publications
0
6
0
Order By: Relevance
“…To date, 30 cases of hemolytic anemia secondary to aortoplasty have been reported in the English literature (Table 2). 628 The reported mechanisms included aortic graft stenosis (50%), graft kinking (23%), external compression of the graft (20%), and a folded elephant trunk appendage (7%). Graft stenosis was largely attributed to the inversion of Teflon strips; however, other cases involving implant narrowing secondary to graft dehiscence or dissection flap obstruction at the distal anastomosis have been reported.…”
Section: Discussionmentioning
confidence: 99%
“…To date, 30 cases of hemolytic anemia secondary to aortoplasty have been reported in the English literature (Table 2). 628 The reported mechanisms included aortic graft stenosis (50%), graft kinking (23%), external compression of the graft (20%), and a folded elephant trunk appendage (7%). Graft stenosis was largely attributed to the inversion of Teflon strips; however, other cases involving implant narrowing secondary to graft dehiscence or dissection flap obstruction at the distal anastomosis have been reported.…”
Section: Discussionmentioning
confidence: 99%
“…Hemolysis after cardiac surgery is a rare but recognized complication, especially as perivalvular leakage after prosthetic valve replacement. However, hemolysis related to an inner felt strip or a kinked prosthetic graft is very rare [ 1 7 ]. We described hemolytic anemia that developed at the site of an inverted Teflon felt strip after ascending aortic replacement.…”
Section: Discussionmentioning
confidence: 99%
“…2 Hepper et al mentioned that hemolysis developed 6 years later due to graft kinking caused by an inappropriate graft length. 4 Hori and colleagues presented a case of hemolytic anemia 4 years after surgery caused by graft compression due to a pseudoaneurysm arising from the proximal anastomosis. 5 As can be seen, these complications developed 4 to 8 years after surgery as these problems are usually associated with extravascular factors.…”
Section: Discussionmentioning
confidence: 99%