Hemolytic anemia caused by aortic flap and inversion of felt strip after ascending aorta replacement

Abstract: BackgroundsHemolysis related to a kinked prosthetic graft or inner felt strip is a very rare complication after aortic surgery. We describe herein a case of hemolytic anemia that developed due to aortic flap of the dissection and inversion of an inner felt strip that was applied at the proximal anastomosis of a replaced ascending aorta 10 years previously.Case presentationA 74-year-old woman presented with consistent hemolytic anemia 10 years after replacement of the ascending aorta to treat Stanford type A ac… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 6 publications
(11 reference statements)
0
8
0
Order By: Relevance
“…Some authors have suggested that the most important imaging finding suggestive of mechanical hemolysis secondary to a graft complication is a ‘mosaic pattern’ on echocardiography representative of turbulent blood flow. 26 This finding, when paired with a typical pattern of laboratory values, should increase suspicion for mechanical hemolysis secondary to graft complications and may prompt reoperation to correct a probable defect.…”
Section: Discussionmentioning
confidence: 95%
See 2 more Smart Citations
“…Some authors have suggested that the most important imaging finding suggestive of mechanical hemolysis secondary to a graft complication is a ‘mosaic pattern’ on echocardiography representative of turbulent blood flow. 26 This finding, when paired with a typical pattern of laboratory values, should increase suspicion for mechanical hemolysis secondary to graft complications and may prompt reoperation to correct a probable defect.…”
Section: Discussionmentioning
confidence: 95%
“…To date, 30 cases of hemolytic anemia secondary to aortoplasty have been reported in the English literature (Table 2). 628 The reported mechanisms included aortic graft stenosis (50%), graft kinking (23%), external compression of the graft (20%), and a folded elephant trunk appendage (7%). Graft stenosis was largely attributed to the inversion of Teflon strips; however, other cases involving implant narrowing secondary to graft dehiscence or dissection flap obstruction at the distal anastomosis have been reported.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Hemolysis after aortic surgery has been reported in several studies. 2 , 3 ) Inverted internal felt strips and severely kinked grafts, which cause accelerated flow and mechanical damage to red blood cell, are the main causes of hemolysis. 2 , 3 ) In contrast, significant AS notably reduced hemoglobin and haptoglobin levels and increased LDH levels, 5 ) indicating that AS also potentially causes hemolysis.…”
Section: Discussionmentioning
confidence: 99%
“…Hemolytic anemia is a rare but possible complication both after aortic valve replacement (AVR) 1 ) and ascending aortic replacement. 2 , 3 ) Reoperative replacement of the aortic valve and the ascending aorta has significant surgical mortality and morbidity, making less invasive approach desirable for high-surgical-risk patients. Here we describe a case of prosthetic aortic valve stenosis and internal bovine pericardial flap in the ascending aorta after surgery for acute aortic dissection complicated by congestive heart failure and hemolytic anemia, which were successfully treated by simultaneous transcatheter aortic valve-in-valve and ascending stent grafting.…”
Section: Introductionmentioning
confidence: 99%