2008
DOI: 10.1088/0031-8949/2008/t132/014021
|View full text |Cite
|
Sign up to set email alerts
|

Classical and ablative Richtmyer–Meshkov instability and other ICF-relevant plasma flows diagnosed with monochromatic x-ray imaging

Abstract: Abstract. In inertial confinement fusion (ICF) and high-energy density physics (HEDP), the most important manifestations of the hydrodynamic instabilities and other mixing processes involve lateral motion of the accelerated plasmas. In order to understand the experimental observations and to advance the numerical simulation codes to the point of predictive capability, it is critically important to accurately diagnose the motion of the dense plasma mass. The most advanced diagnostic technique recently developed… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2010
2010
2014
2014

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 74 publications
(97 reference statements)
0
6
0
Order By: Relevance
“…A modification of the traditional x-ray monochromatic backlighting scheme is the x-ray crystal imaging microscope (XCIM), [6][7][8][9][10] where the Bragg angles can deviate substantially a) Contributed paper, published as part of the Proceedings of the 20th Topical Conference on High-Temperature Plasma Diagnostics, Atlanta, Georgia, USA, June 2014. b) Author to whom correspondence should be addressed. Electronic mail:…”
Section: Introductionmentioning
confidence: 99%
“…A modification of the traditional x-ray monochromatic backlighting scheme is the x-ray crystal imaging microscope (XCIM), [6][7][8][9][10] where the Bragg angles can deviate substantially a) Contributed paper, published as part of the Proceedings of the 20th Topical Conference on High-Temperature Plasma Diagnostics, Atlanta, Georgia, USA, June 2014. b) Author to whom correspondence should be addressed. Electronic mail:…”
Section: Introductionmentioning
confidence: 99%
“…So the convergent ablator performances can be inferred with more accurately. This high spatial resolution diagnostics with high magnification will also be helpful to observe the RayleighTaylor bubble and spike features from backlit radiographs 15,24,25 in future. …”
Section: Discussionmentioning
confidence: 94%
“…The spectral resolution is not larger than 1 Â 10 À3 k in our configuration. A contrast aperture of 2 mm in diameter in the reflected beam is used to protect the detector from a significant portion of the self-radiation 14,15 as shown in Fig. 1.…”
Section: Experimental Configurationmentioning
confidence: 99%
See 1 more Smart Citation
“…Monochromatic backlighters, based on Bragg reflection near normal incidence from a spherically bent crystal, 2, 3 have previously been used to image wire-array Z-pinches and pulsed-power-driven HEDP experiments 4 and laser-plasma interactions relevant to Inertial Confinement Fusion. 5,6 A monochromatic backlighter has been developed for the study of HEDP experiments on MAGPIE, 1 a pulsed power generator capable of producing a 1.4 MA electrical pulse with a rise time of 240 ns. This instrument uses a spherically bent quartz 1011 crystal to perform radiography with 1.865 keV X-rays (Silicon He-α) driven by a ≈7 J, ≈1 ns, 527 nm pulse from a long-pulse arm of the Cerberus multibeam laser system.…”
Section: Introductionmentioning
confidence: 99%