2015
DOI: 10.1371/journal.pone.0122191
|View full text |Cite
|
Sign up to set email alerts
|

Circumpapillary Course of Retinal Pigment Epithelium Can Be Fit to Sine Wave and Amplitude of Sine Wave Is Significantly Correlated with Ovality Ratio of Optic Disc

Abstract: The purpose of this study was to develop a method of quantifying the degree of optic disc tilt in normal eyes. This was a prospective, observational cross sectional study of 126 right eyes of 126 healthy volunteers. The optic disc tilt was determined from the circular peripapillary optical coherence tomographic (OCT) scan images. The course of the retinal pigment epithelium (RPE) layer in the peripapillary cross sectional scan images was fit to a sine wave curve, and the amplitude of the sine curve was used to… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
16
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 16 publications
(16 citation statements)
references
References 25 publications
0
16
0
Order By: Relevance
“…All eyes had a standard ocular examination as reported elsewhere [27, 28] including; slit-lamp biomicroscopy of the anterior segment, ophthalmoscopy of the ocular fundus, pneumo-tonometric (CT-80, Topcon, Tokyo, Japan) measurements of the IOP, and AL-2000 ultrasonographic (TOMEY, Nagoya, Japan) measurements of the axial length. The refractive error (spherical equivalent) was measured with the Topcon KR8800 autorefractometer/keratometer.…”
Section: Subjectsmentioning
confidence: 99%
See 3 more Smart Citations
“…All eyes had a standard ocular examination as reported elsewhere [27, 28] including; slit-lamp biomicroscopy of the anterior segment, ophthalmoscopy of the ocular fundus, pneumo-tonometric (CT-80, Topcon, Tokyo, Japan) measurements of the IOP, and AL-2000 ultrasonographic (TOMEY, Nagoya, Japan) measurements of the axial length. The refractive error (spherical equivalent) was measured with the Topcon KR8800 autorefractometer/keratometer.…”
Section: Subjectsmentioning
confidence: 99%
“…Degree of optic disc tilt was determined by our method reported previously [27]. In brief, the course of the retinal pigment epithelium (RPE) was marked on the OCT B-scan images manually.…”
Section: Subjectsmentioning
confidence: 99%
See 2 more Smart Citations
“…25 Briefly, the optic disc tilt was quantified using a sine curve method of the Topcon 3D OCT-1000 Mark II RNFL 3.4-mm circle scan, B scan images. The course of the RPE was marked on the B-scan images manually.…”
Section: Assessment Of Pnfe Conus and Optic Disc Tiltmentioning
confidence: 99%