2001
DOI: 10.1148/radiology.219.3.r01jn44828
|View full text |Cite
|
Sign up to set email alerts
|

Cine MR Angiography of the Heart with Segmented True Fast Imaging with Steady-State Precession

Abstract: In five healthy subjects and 18 patients, cine magnetic resonance (MR) imaging of the heart was performed with a true fast imaging with steady-state precession (FISP) sequence. Results were compared both quantitatively and qualitatively with those at cine fast low-angle shot (FLASH) MR imaging. The blood-myocardial contrast-to-noise ratio (CNR) was 2.0 times higher and the normalized (for measurement time and pixel size) blood-myocardial CNR was 4.0 times higher for true FISP compared with FLASH MR imaging. Qu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
287
0
2

Year Published

2003
2003
2021
2021

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 430 publications
(290 citation statements)
references
References 12 publications
1
287
0
2
Order By: Relevance
“…Meanwhile, true SSFP is based on a gradient echosequence and recycles steady-state transverse magnetization in long T2 substances. The steady-state signal is dependent on the T2-to-T1 ratio, which is relatively high for blood and has been used successfully in vascular imaging (17,18). It allows visualization of the vessels with high flow velocity and narrow diameter, such as the hepatic artery, without an intravenous contrast agent (11).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Meanwhile, true SSFP is based on a gradient echosequence and recycles steady-state transverse magnetization in long T2 substances. The steady-state signal is dependent on the T2-to-T1 ratio, which is relatively high for blood and has been used successfully in vascular imaging (17,18). It allows visualization of the vessels with high flow velocity and narrow diameter, such as the hepatic artery, without an intravenous contrast agent (11).…”
Section: Discussionmentioning
confidence: 99%
“…For better visualization of blood in the body region, 3D half-Fourier fast spin-echo (FSE) sequence and true steady-state freeprecession (SSFP) sequences are widely used for non-CE MRA (11)(12)(13)(14)(15)(16)(17)(18)(19). They allow coronal acquisition that is not possible with time-of-flight imaging, especially for body MRA, and thus reduces acquisition time.…”
mentioning
confidence: 99%
“…The recently introduced SSFP sequences enable shorter acquisition times, allow higher in-plane resolutions, and provide better image quality (8,9). Their accuracy in determining left ventricular (LV) mass was also evaluated in animal experiments (10).…”
Section: Cine Magnetic Resonance (Mr) Imaging Has Beenmentioning
confidence: 99%
“…Contrast between intraventricular blood and myocardium as well as between myocardium and epicardial fat is significantly higher in images obtained with SSFP sequences compared to those acquired with TGE sequences (8,9), and thus improves the automatic detection of endocardial contours (11,12). The SSFP sequence is therefore considered to be the sequence of choice for the assessment of ventricular function (13).…”
Section: Cine Magnetic Resonance (Mr) Imaging Has Beenmentioning
confidence: 99%
“…However, the analysis of tagged images requires sufficient myocardial signal-to-noise ratio (SNR) and tag-myocardium contrast-to-noise ratio (CNR) for accurate tag detection (9 -12). Refocused steady-state free precession (SSFP) (13), also known as fast imaging with steady precession (FISP or TrueFISP) (14,15), has proven valuable for in vivo cardiac functional MRI because of its high tissue SNR and excellent myocardium-to-blood CNR (16,17). Therefore, the analysis of tagged images may be improved with the increased SNR and inherent contrast of an SSFP acquisition.…”
mentioning
confidence: 99%