Surgical options for cartilage resurfacing may be significantly improved by advances and application of biomaterials that direct tissue repair. A poly(ethylene glycol) diacrylate (PEGDA) hydrogel was designed to support cartilage matrix production, with easy surgical application. A model in vitro system demonstrated deposition of cartilage-specific extracellular matrix in the hydrogel biomaterial and stimulation of adjacent cartilage tissue development by mesenchymal stem cells. For translation to the joint environment, a chondroitin sulfate adhesive was applied to covalently bond and adhere the hydrogel to cartilage and bone tissue in articular defects. After preclinical testing in a caprine model, a pilot clinical study was initiated where the biomaterials system was combined with standard microfracture surgery in 15 patients with focal cartilage defects on the medial femoral condyle. Control patients were treated with microfracture alone. Magnetic resonance imaging showed that treated patients achieved significantly higher levels of tissue fill compared to controls. Magnetic resonance spin-spin relaxation times (T2) showed decreasing water content and increased tissue organization over time. Treated patients had less pain compared with controls, whereas knee function [International Knee Documentation Committee (IKDC)] scores increased to similar levels between the groups over the 6 months evaluated. No major adverse events were observed over the study period. With further clinical testing, this practical biomaterials strategy has the potential to improve the treatment of articular cartilage defects.
Fat suppression is an important technique in musculoskeletal imaging to improve the visibility of bone-marrow lesions; evaluate fat in soft-tissue masses; optimize the contrast-to-noise ratio in magnetic resonance (MR) arthrography; better define lesions after administration of contrast material; and avoid chemical shift artifacts, primarily at 3-T MR imaging. High-field-strength (eg, 3-T) MR imaging has specific technical characteristics compared with lower-field-strength MR imaging that influence the use and outcome of various fat-suppression techniques. The most commonly used fat-suppression techniques for musculoskeletal 3-T MR imaging include chemical shift (spectral) selective (CHESS) fat saturation, inversion recovery pulse sequences (eg, short inversion time inversion recovery [STIR]), hybrid pulse sequences with spectral and inversion-recovery (eg, spectral adiabatic inversion recovery and spectral attenuated inversion recovery [SPAIR]), spatial-spectral pulse sequences (ie, water excitation), and the Dixon techniques. Understanding the different fat-suppression options allows radiologists to adopt the most appropriate technique for their clinical practice.
Fibrous cap thickness is often considered as diagnostic of the degree of plaque instability. Necrotic core area (Core(area)) and the arterial remodeling index (Remod(index)), on the other hand, are difficult to use as clinical morphological indexes: literature data show a wide dispersion of Core(area) thresholds above which plaque becomes unstable. Although histopathology shows a strong correlation between Core(area) and Remod(index), it remains unclear how these interact and affect peak cap stress (Cap(stress)), a known predictor of rupture. The aim of this study was to investigate the change in plaque vulnerability as a function of necrotic core size and plaque morphology. Cap(stress) value was calculated on 5,500 idealized atherosclerotic vessel models that had the original feature of mimicking the positive arterial remodeling process described by Glagov. Twenty-four nonruptured plaques acquired by intravascular ultrasound on patients were used to test the performance of the associated idealized morphological models. Taking advantage of the extensive simulations, we investigated the effects of anatomical plaque features on Cap(stress). It was found that: 1) at the early stages of positive remodeling, lesions were more prone to rupture, which could explain the progression and growth of clinically silent plaques and 2) in addition to cap thickness, necrotic core thickness, rather than area, was critical in determining plaque stability. This study demonstrates that plaque instability is to be viewed not as a consequence of fibrous cap thickness alone but rather as a combination of cap thickness, necrotic core thickness, and the arterial remodeling index.
Purpose: To evaluate the error in T1 estimates using inversion-recovery-based T1 mapping due to imperfect inversion and to perform a systematic study of adiabatic inversion pulse designs in order to maximize inversion efficiency for values of transverse relaxation (T2) in the myocardium subject to a peak power constraint. Methods: The inversion factor for hyperbolic secant and tangent/hyperbolic tangent adiabatic full passage waveforms was calculated using Bloch equations. A brute-force search was conducted for design parameters: pulse duration, frequency range, shape parameters, and peak amplitude. A design was selected that maximized the inversion factor over a specified range of amplitude and off-resonance and validated using phantom measurements. Empirical correction for imperfect inversion was performed. Results: The tangent/hyperbolic tangent adiabatic pulse was found to outperform hyperbolic secant designs and achieve an inversion factor of 0.96 within 6150 Hz over 25% amplitude range with 14.7 mT peak amplitude. T1 mapping errors of the selected design due to imperfect inversion was $4% and could be corrected to <1%. Conclusions: Nonideal inversion leads to significant errors in inversion-recovery-based T1 mapping. The inversion efficiency of adiabatic pulses is sensitive to transverse relaxation. The tangent/hyperbolic tangent design achieved the best performance subject to the peak amplitude constraint.
Background-Accurate knowledge of the human atrial fibrous structure is paramount in understanding the mechanisms of atrial electric function in health and disease. Thus far, such knowledge has been acquired from destructive sectioning, and there is a paucity of data about atrial fiber architecture variability in the human population. Methods and Results-In this study, we have developed a customized 3-dimensional diffusion tensor magnetic resonance imaging sequence on a clinical scanner that makes it possible to image an entire intact human heart specimen ex vivo at submillimeter resolution. The data from 8 human atrial specimens obtained with this technique present complete maps of the fibrous organization of the human atria. The findings demonstrate that the main features of atrial anatomy are mostly preserved across subjects although the exact location and orientation of atrial bundles vary. Using the full tractography data, we were able to cluster, visualize, and characterize the distinct major bundles in the human atria. Furthermore, quantitative characterization of the fiber angles across the atrial wall revealed that the transmural fiber angle distribution is heterogeneous throughout different regions of the atria. Conclusions-The application of submillimeter diffusion tensor magnetic resonance imaging provides an unprecedented level of information on both human atrial structure, as well as its intersubject variability. The high resolution and fidelity of this data could enhance our understanding of structural contributions to atrial rhythm and pump disorders and lead to improvements in their targeted treatment. (Circ Arrhythm Electrophysiol. 2016;9:e004133.
Background Previous studies suggest that MRI with late gadolinium enhancement (LGE) may identify slowly conducting tissues in scar-related ventricular tachycardia (VT). Objective We tested the feasibility of image-based simulation based on LGE to estimate ablation targets in VT. Methods We conducted a retrospective study in 13 patients who had pre-ablation MRI for scar-related VT ablation. We used image-based simulation to induce VT and estimate target regions according to the simulated VT circuit. The estimated target regions were co-registered with the LGE scar map and the ablation sites from the electroanatomical map in the standard ablation approach. Results In image-based simulation, VT was inducible in 12 patients (92.3%). All VTs showed macro-reentrant propagation patterns, and the narrowest width of estimated target region that an ablation line should span to prevent VT recurrence was 5.0 ± 3.4 mm. Out of 11 patients who underwent ablation, the results of image-based simulation and the standard approach were consistent in 9 patients (82%), where ablation within the estimated target region was associated with acute success (n=8) and ablation outside the estimated target region was associated with failure (n=1). In one case (9%), the results of image-based simulation and the standard approach were inconsistent, where ablation outside the estimated target region was associated with acute success. Conclusions The image-based simulation can be used to estimate potential ablation targets of scar-related VT. The image-based simulation may be a powerful noninvasive tool for pre-procedural planning of ablation procedures to potentially reduce the procedure time and complication rates.
Local susceptibility gradients result in a dephasing of the precessing magnetic moments and thus in a fast decay of the NMR signals. In particular, cells labeled with superparamagnetic iron oxide particles (SPIOs) induce hypointensities, making the in vivo detection of labeled cells from such a negative image contrast difficult. In this work, a new method is proposed to selectively turn this negative contrast into a positive contrast. The proposed method calculates the susceptibility gradient and visualizes it in a parametric map directly from a regular gradient-echo image dataset. The susceptibility gradient map is determined in a postprocessing step, requiring no dedicated pulse sequences or adaptation of the sequence before and during image acquisition. Phantom experiments demonstrated that local susceptibility differences can be quantified. In vivo experiments showed the feasibility of the method for tracking of SPIO-labeled cells. The method bears the potential also for usage in other applications, including the detection of contrast agents and interventional devices as well as metal implants.
BackgroundMyocardial T1-mapping methods such as MOLLI use SSFP readout and are prone to frequency-dependent error in T1-measurement. A significant error in T1 may result at relatively small off-resonance frequencies that are well within the region without banding artifacts.MethodsThe sensitivity of T1-estimates based on the SSFP based MOLLI sequence to errors in center frequency are calculated by means of a Bloch simulation and validated by phantom measurements. Typical off-resonance errors following local cardiac shimming are determined by field mapping at both 1.5 and 3.0T. In vivo examples demonstrate the artifactual appearance of T1-maps in the presence of off-resonance variation.ResultsOff-resonance varied 61.8 ± 15.5 Hz (mean ± SD, n = 18) across the heart at 1.5T and 125.0 ± 40.6 Hz (mean ± SD, n = 18) at 3.0T. For T1 = 1000 ms, the variation in T1 due to off-resonance variation was approximately 20 ms at 62 Hz, and > 50 ms at 125 Hz.ConclusionsRegional variations due to the inability to completely shim the B0-field variation around the heart appear as regional variation in T1, which is artifactual.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.