1972
DOI: 10.1080/00327487208061469
|View full text |Cite
|
Sign up to set email alerts
|

Chromatography of Biological Materials on Polyethylene Glycol Treated Controlled-Pore Glass

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0

Year Published

1976
1976
2008
2008

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 58 publications
(8 citation statements)
references
References 12 publications
0
8
0
Order By: Relevance
“…The coelution of the virus at the column Vo was expected, since the mean pore diameter of the CPG was seleeted to exclude particles with diameters greater than about 750 A_ (5,7,9). The slight inclusion of bovine serum albumin into the column was unexpected and may reflect the erratic etution properties of CPG eotumn packings when soluble proteins are sieved through this type of chromatographic medium (9).…”
Section: Column E//iciency Evaluationmentioning
confidence: 96%
See 1 more Smart Citation
“…The coelution of the virus at the column Vo was expected, since the mean pore diameter of the CPG was seleeted to exclude particles with diameters greater than about 750 A_ (5,7,9). The slight inclusion of bovine serum albumin into the column was unexpected and may reflect the erratic etution properties of CPG eotumn packings when soluble proteins are sieved through this type of chromatographic medium (9).…”
Section: Column E//iciency Evaluationmentioning
confidence: 96%
“…The slight inclusion of bovine serum albumin into the column was unexpected and may reflect the erratic etution properties of CPG eotumn packings when soluble proteins are sieved through this type of chromatographic medium (9).…”
Section: Column E//iciency Evaluationmentioning
confidence: 99%
“…PEO surfaces have but for other areas as well, such as membranes for been prepared by physical adsorption of PEO onto exseparation processes, biosensors, chromatographic isting substrates. [18][19][20][21] Only high-molecular-weight PEO supports, contact lenses, immunoassay, blood, and (mol. wt.…”
Section: Introductionmentioning
confidence: 99%
“…A series of 25, 50, and 250 ml beakers (Pyrex™ glass and Teflon®) were examined as well as 20 ml plastic high-density polyethylene (HDPE) vials and treated and non-treated borosilicate glass scintillation vials. One set of glass scintillation vials was treated with an aqueous 5% polyethylene glycol (PEG; 20,000 MW; Avocado Research Chemicals Ltd.; Heysham, UK) solution according to Hawk et al (1972). Vials were filled with the PEG solution for 5 min, drained, and then dried at 120°C overnight under vacuum.…”
mentioning
confidence: 99%