2012
DOI: 10.1590/s0103-50532012000400023
|View full text |Cite
|
Sign up to set email alerts
|

Chromatographic analyses of fatty acid methyl esters by HPLC-UV and GC-FID

Abstract: Um método analítico por cromatografia líquida de alto rendimento com detecção ultravioleta (HPLC-UV) (método A) foi utilizado na determinação simultânea dos valores totais de triacilglicerídeos, diacilglicerídeos, monoacilglicerídeos e ésteres metílicos de ácidos graxos na alcólise de diferentes óleos (algodão, canola, girassol, milho e soja). As análises foram realizadas a 40 °C por 20 min usando gradiente de metanol (MeOH) e 2-propanol-hexano 5:4 (v/v) (PrHex): 100% de MeOH em 0 min, 50% de MeOH e 50% de PrH… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
56
1
6

Year Published

2014
2014
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 85 publications
(66 citation statements)
references
References 17 publications
(31 reference statements)
3
56
1
6
Order By: Relevance
“…Many product hydrolyses will detect in analysis TGA using HPLC-UV. This result was reported by Carvalho et al [20] that the HPLC-UV can analyze the methyl ester, free fatty acid, monoglycerides, diglycerides, and TGA with different retention times. Hence, this is evidence to controlling the process of making the meatball.…”
Section: Resultssupporting
confidence: 76%
“…Many product hydrolyses will detect in analysis TGA using HPLC-UV. This result was reported by Carvalho et al [20] that the HPLC-UV can analyze the methyl ester, free fatty acid, monoglycerides, diglycerides, and TGA with different retention times. Hence, this is evidence to controlling the process of making the meatball.…”
Section: Resultssupporting
confidence: 76%
“…oil, it was analyzed the final composition of the sample by high performance liquid chromatography (HPLC) using a method published elsewhere. 13 The reaction was followed up by Fourier transform infrared spectroscopy (FTIR) and 1H nuclear magnetic resonance ( 1 H NMR). FTIR was obtained using a Shimadzu Prestige-21 equipment, with an attenuated total reflectance (ATR) cell, 7 mm optical path and 10 reflections, using a nominal spectral resolution of 4 cm -1 and 32 scans.…”
Section: Preparation Of Biodiesel From Chlorella Sp and Biosolidmentioning
confidence: 99%
“…The analysis was conducted following a method described in the literature. 13 The solvent gradient consists of 100% methanol and 0% isopropanol/hexane (5:4, v:v) in 0 min. The concentration of the isopropanol/hexane mixture (5:4 v:v) gradually increases until 10 min of analysis when it reaches 50:50 v:v with methanol, maintaining the mixture up to 17 min, when methanol is raised again to 100% up to 23 min, finishing the analysis.…”
Section: Hplc Analysismentioning
confidence: 99%
“…The FAME content in the final product was measured by high-performance liquid chromatography (HPLC), resulting in a conversion of 98.5%. 30 Standard and real samples preparation 21 standard samples were prepared with known amounts of fatty acids and FAME (binary mixture, m/m) with concentrations in the range of 0-100% in 5% steps, at room temperature, using a semi-analytical scale (Mettler, ± 0.001 g). The acid indexes for all samples were first determined by titration (method AOCS Cd 3a-63): 0.3 g of the sample was dissolved in a mixture of toluene and isopropylic alcohol (1:1, v:v) and then titrated with an alcoholic solution of KOH (0.1 M) using phenolphthalein as indicator.…”
Section: Biodiesel Synthesismentioning
confidence: 99%