2006
DOI: 10.1016/j.chroma.2006.03.077
|View full text |Cite
|
Sign up to set email alerts
|

Chiral separation of acidic drug components by open tubular electrochromatography using avidin immobilized capillaries

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
42
0

Year Published

2007
2007
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 50 publications
(44 citation statements)
references
References 51 publications
2
42
0
Order By: Relevance
“…Moreover, most of the coupling methods applied are built-up or developed in-house and experience in the fabrication and handling is needed [36]. As has been also reviewed by Klampfl [4], developments of the interface were reported [36,37], although more papers address better solutions for the capillary fabrication such as the use of novel separation materials [38][39][40][41], improvements of the packing method [42] or alternations of the separation capillary [43].…”
Section: Trends In Cec-msmentioning
confidence: 96%
See 1 more Smart Citation
“…Moreover, most of the coupling methods applied are built-up or developed in-house and experience in the fabrication and handling is needed [36]. As has been also reviewed by Klampfl [4], developments of the interface were reported [36,37], although more papers address better solutions for the capillary fabrication such as the use of novel separation materials [38][39][40][41], improvements of the packing method [42] or alternations of the separation capillary [43].…”
Section: Trends In Cec-msmentioning
confidence: 96%
“…4 [45]. Another application was published recently based on the chemical immobilization of avidin onto the fused-silica surface, which provided a possibility to separate acidic drug components in affinity mode (ACEC) [39].…”
Section: Trends In Cec-msmentioning
confidence: 99%
“…A good example is the use of covalently immobilized avidin on the capillary surface to produce a stable coating with chiral recognition and MS compatibility (19). Avidin-modified coatings showed good chiral recognition for abscisic acid enantiomers and lasted 50 days with over 100 runs.…”
Section: Capillary Coatings and Surface Modificationsmentioning
confidence: 99%
“…Kitagawa et al [86] immobilized an avidin selector in OT CEC to produce more stable columns compared with the classically coated column. Run-to-run repeatability for migration time had an RSD of 0.8%, while interday repeatability for Rs was below 8.9%.…”
Section: Applications In Ot Cecmentioning
confidence: 99%