1971
DOI: 10.1002/chin.197150067
|View full text |Cite
|
Sign up to set email alerts
|

ChemInform Abstract: (73)GE‐NMR‐UNTERSUCHUNGEN

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

1977
1977
2002
2002

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 1 publication
0
4
0
Order By: Relevance
“…Of course, the accuracy of the result clearly depends on what the Another situation where isotope shifts have some effect is when signals of the reference compound are affected, for instance for 19 F measurements. In this case, the signal is split into four lines with intensities approximately 27:27:9:1 because the natural-abundance isotopic ratio 35 Cl: 37 Cl is ca. 3:1.…”
Section: Referencing Proceduresmentioning
confidence: 99%
“…Of course, the accuracy of the result clearly depends on what the Another situation where isotope shifts have some effect is when signals of the reference compound are affected, for instance for 19 F measurements. In this case, the signal is split into four lines with intensities approximately 27:27:9:1 because the natural-abundance isotopic ratio 35 Cl: 37 Cl is ca. 3:1.…”
Section: Referencing Proceduresmentioning
confidence: 99%
“…In such situations the correction term in parentheses in Eqn (8) Another situation where isotope shifts have some effect is when signals of the reference compound are affected, for instance for 19 F measurements. In this case the signal is split into four lines with intensities approximately 27 : 27 : 9 : 1 because the natural-abundance isotopic ratio 35 Cl : 37 Cl is ca 3 : 1. Since CFCl 3 is firmly accepted as the local reference for 19 F, it is not reasonable to suggest a new alternative.…”
Section: Referencing Proceduresmentioning
confidence: 99%
“…Since CFCl 3 is firmly accepted as the local reference for 19 F, it is not reasonable to suggest a new alternative. It is recommended that the reference signal is that of CF 35 Cl 2 37 Cl). Earlier IUPAC documentation 1,2 did not suggest any specific composition for the reference sample or choice of solvents.…”
Section: Referencing Proceduresmentioning
confidence: 99%
“…2919; Uvasol). The 73Ge and 39K reference samples were GeC14 (a neat liquid) and a 31 molal solution of KNO 2 in D20 ; both samples were used in former work and described there [6,8,9].…”
Section: Samplesmentioning
confidence: 99%