“…The intensity of the emitting light was proportional to the amount of enzyme present and was inversely related to the amount of unlabelled T 3 in the sample. By reference to a series of T 3 standards assayed in the same way, the concentration of T 3 in the unknown sample was quantified (Rongen et al, 1994). The precise method for T 3 was repeated for T 4 .…”
Section: Physiological Parametersmentioning
confidence: 99%
See 1 more Smart Citation
“…The intensity of the emitting light was proportional to the amount of enzyme present and was inversely related to the amount of unlabelled T 3 in the sample. By reference to a series of T 3 standards assayed in the same way, the concentration of T 3 in the unknown sample was quantified (Rongen et al, 1994). The precise method for T 3 was repeated for T 4 .…”
Section: Physiological Parametersmentioning
confidence: 99%
“…In the T 3 CLIA, as explained by Rongen et al (1994), a certain amount of anti-T 3 antibody was coated on micro titer wells. A measured amount of chicken serum and a constant amount of T 3 conjugated with horseradish peroxidase were added to the micro titer wells.…”
Section: Physiological Parametersmentioning
confidence: 99%
“…The TSH CLIA test utilises a unique monoclonal antibody directed against a distinct antigenic determinant on the intact TSH molecule [14]. The mean TSH values based on 160 random normal adult blood samples is 2.2 (0.27-4.2) μIU/ml.…”
Section: Tsh Analysesmentioning
confidence: 99%
“…6 Chemiluminescence (CL) has been exploited with a wide range of applications in different fields, such as biotechnology, pharmacology, molecular biology, and clinical and environmental chemistries. [7][8][9][10] However, only one CL method was reported for the determination of MP, which was based on reactions among tris-(2,2′-bipyridine)ruthenium(II), MP, hydrogen peroxide, Tween 20 and hydroxide ion. 11 In this method, the mixing order of the reagents considerably affects the CL signal.…”
Section: Introductionmentioning
confidence: 99%