2014
DOI: 10.1002/mrm.25473
|View full text |Cite
|
Sign up to set email alerts
|

Chemical shift separation with controlled aliasing for hyperpolarized 13C metabolic imaging

Abstract: Purpose A chemical shift separation technique for hyperpolarized 13C metabolic imaging with high spatial and temporal resolution was developed. Specifically, a fast 3D pulse sequence and a reconstruction method were implemented to acquire signals from multiple 13C species simultaneously with subsequent separation into individual images. Methods A stack of flyback-EPI readouts and a set of multiband excitation RF pulses were designed to spatially modulate aliasing patterns of the acquired metabolite images, w… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
23
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(23 citation statements)
references
References 38 publications
0
23
0
Order By: Relevance
“…SENSE has been used to reduce 2D acquisition from 43 seconds to 14 seconds [162], and parallel imaging with EPSI has been used to collect 3D pyruvate and lactate images from rat kidneys in a few seconds [163]. …”
Section: Magnetic Resonance Spectroscopic Imagingmentioning
confidence: 99%
“…SENSE has been used to reduce 2D acquisition from 43 seconds to 14 seconds [162], and parallel imaging with EPSI has been used to collect 3D pyruvate and lactate images from rat kidneys in a few seconds [163]. …”
Section: Magnetic Resonance Spectroscopic Imagingmentioning
confidence: 99%
“…Others have used single‐band SpSp pulses to image a single metabolite at a time, for example with 2D and 3D echo planar imaging (EPI), which can be accelerated with compressed sensing . The EPI trajectory can also be designed to enable separation of metabolite resonances in the resulting images . Spiral chemical shift imaging (CSI) has been studied extensively, while traditional CSI with compressed sensing has also shown promise for dynamic measurements .…”
Section: Introductionmentioning
confidence: 99%
“…We recently proposed a single‐shot 3D sequence that makes efficient use of the transverse magnetization after each excitation . The sequence exploits the B 1 insensitivity of adiabatic pulses, following a dual‐spin‐echo (DSE) scheme that is widely used in other hyperpolarized MRI applications . The adiabatic pulses in the DSE scheme result in better refocusing and hence less signal loss due to dephasing, but the pulse sequence is inefficient in its use of spin hyperpolarization, since signal is acquired from only half of the spin echoes.…”
Section: Introductionmentioning
confidence: 99%
“…For 13 C receive, an 8-channel array coil was used with 2 sets of four coil elements in a linear arrangement as shown in Fig. 1(a) [24,25]. Each rectangular element was approximately 5 × 10 cm and adjacent elements were overlapped to minimize mutual inductance.…”
Section: Methodsmentioning
confidence: 99%