2009
DOI: 10.1088/0960-1317/19/7/074022
|View full text |Cite
|
Sign up to set email alerts
|

Characterization of thermal cross-talk in a MEMS-based thermopile detector array

Abstract: The spectral resolution of a MEMS-based IR microspectrometer critically depends on the thermal cross-talk between adjacent TE elements in the detector array. Thermal isolation between elements is realized by using bulk micromachining directly following CMOS processing. This paper reports on the characterization results of bridge-shaped TE detector elements that are cut out of a membrane. Elements with dimensions of 650 × 36 μm 2 are separated by 10 μm wide gaps in order to minimize the thermal cross-talk by he… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
24
0
1

Year Published

2010
2010
2024
2024

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 39 publications
(28 citation statements)
references
References 6 publications
2
24
0
1
Order By: Relevance
“…The voltage bias also varied from -5V to 5V with steps of 0.1V. According to the equations in previous literatures [6][7][8] the Rs and D* are derived. The derived Rs of the n-type thermopile without vacuum is 31.9 V/W.…”
Section: A Characterization Of the Conventional Planar Thermopilementioning
confidence: 99%
“…The voltage bias also varied from -5V to 5V with steps of 0.1V. According to the equations in previous literatures [6][7][8] the Rs and D* are derived. The derived Rs of the n-type thermopile without vacuum is 31.9 V/W.…”
Section: A Characterization Of the Conventional Planar Thermopilementioning
confidence: 99%
“…The thermo-electric elements are N-and P-type doped thin-film polysilicon wires. Details of the fabrication of these devices can be found in [6] [7]. The thickness of the membrane and thennopile strips is typically a few hundred nanometers.…”
Section: General Thermal Analysis Of a Thin Film Beammentioning
confidence: 99%
“…Measurements on thermopile arrays have been reported in [6] and more tests of the thermopile and TCD devices are in progress to verifY their operation and the thermal modeling presented, Figure 9 Since accurately calibrated gas mixtures were not available the relation between the thermopile output voltage and the gas thermal conductivity could not be experimentally verified.…”
Section: Measurementsmentioning
confidence: 99%
“…The thermal transfer due to these three mechanisms acting on the TE element is described in detail in literature 5 . An array of 26 TE elements, each on a bridge structure of 650×36 μm 2 is designed and fabricated.…”
Section: Introductionmentioning