2001
DOI: 10.1021/cc000101t
|View full text |Cite
|
Sign up to set email alerts
|

Characterization of Small Combinatorial Chemistry Libraries by 1H NMR. Quantitation with a Convenient and Novel Internal Standard

Abstract: A novel silane standard, 1,4-bis(trimethylsilyl)benzene (BTMSB), is introduced for the generic quantitation of small organic molecules in DMSO-d(6) solution by (1)H NMR. This standard is an easily weighable solid and is stable for at least 1 month in DMSO solution, and its (1)H NMR spectrum contains a strong singlet in a region usually free of signals. With a set of certified standards, concentration determination with about 2% precision and accuracy is verified after solution preparation with fully automated … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
33
0

Year Published

2005
2005
2016
2016

Publication Types

Select...
6
3

Relationship

2
7

Authors

Journals

citations
Cited by 30 publications
(33 citation statements)
references
References 14 publications
0
33
0
Order By: Relevance
“…In any case, the intensity and phase response should be checked using a sample with a single intense line and varying its position in the spectral window. If the response is found non-linear but reproducible in the range of interest, a correction function can be introduced [13]. This takes into account the off-resonance effect due to non-constant excitation of the rf pulse, as well.…”
Section: Principles Of Nmr Quantificationmentioning
confidence: 99%
“…In any case, the intensity and phase response should be checked using a sample with a single intense line and varying its position in the spectral window. If the response is found non-linear but reproducible in the range of interest, a correction function can be introduced [13]. This takes into account the off-resonance effect due to non-constant excitation of the rf pulse, as well.…”
Section: Principles Of Nmr Quantificationmentioning
confidence: 99%
“…Both DSA (4,4-dimethyl-4-silapentane-1-ammonium trifluoroacetate) and dioxane have been used for protein samples because they were shown to not interact with proteins [25,29]. The internal standard N,N 0 ,N 00 -trimethyl(2-trimethyl) ethylammonium iodide (TMS-A) was proposed as a way to minimize some of the limitations of TSP and DSS [30], and other compounds have been proposed to minimize some of the limitations of TMS [31][32][33].…”
Section: Introductionmentioning
confidence: 99%
“…The purity of compounds 3a-e were measured by the internal standard method using 1,4-bis(trimethylsilyl) benzene. 38) Reagents and conditions: (a) NaBH 4 , MeOH, 0°C, 83%; (b) tert-butyl 4-(3-bromopropyl)piperidine-1-carboxylate, NaH, DMF, r.t., 29%; (c) 4 M HCl-AcOEt, r.t., 75%. 2 mmol).…”
Section: Methodsmentioning
confidence: 99%