2015
DOI: 10.1088/1742-6596/611/1/012004
|View full text |Cite
|
Sign up to set email alerts
|

Characterization of neutron calibration fields at the TINT's 50 Ci americium-241/beryllium neutron irradiator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
4
0
1

Year Published

2017
2017
2021
2021

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(5 citation statements)
references
References 3 publications
0
4
0
1
Order By: Relevance
“…Nötronmetrelerdeki radyoaktif kaynak genellikle Amerikyum-241/Berilyum (Am/Be) karışımı bir maddeden oluşur. Amerikyum-241/Berilyum nötron saçan bir kaynaktır ve ziraat dışında; petrol mühendisliği ve endüstri gibi sektörlerde kullanılır [36]. Bu radyoaktif kaynağa sahip nötron prob çakılan tüplerin içinden ölçülmek istenen derinliğe kadar sarkıtılır.…”
Section: Nötron Saçılımı Yöntemi (Nötronmetreler)unclassified
“…Nötronmetrelerdeki radyoaktif kaynak genellikle Amerikyum-241/Berilyum (Am/Be) karışımı bir maddeden oluşur. Amerikyum-241/Berilyum nötron saçan bir kaynaktır ve ziraat dışında; petrol mühendisliği ve endüstri gibi sektörlerde kullanılır [36]. Bu radyoaktif kaynağa sahip nötron prob çakılan tüplerin içinden ölçülmek istenen derinliğe kadar sarkıtılır.…”
Section: Nötron Saçılımı Yöntemi (Nötronmetreler)unclassified
“…For each batch, 4 OSLN dosimeters were placed on a water phantom (30 cm width × 30 cm height × 15 cm thick) facing the center of the neutron beam, as shown in Figure 3. The reference neutron field was produced by TINT's 50 Ci 241 AmBe neutron irradiator [1]. Neutron irradiation was done at 100 cm distance from the source with the rectangular beam of 26.7 cm x 26.7 cm and the beam homogeneity of 10.6% (standard deviation of the average neutron dose equivalent rate of the field).…”
Section: Neutron Irradiationmentioning
confidence: 99%
“…Neutron irradiation was done at 100 cm distance from the source with the rectangular beam of 26.7 cm x 26.7 cm and the beam homogeneity of 10.6% (standard deviation of the average neutron dose equivalent rate of the field). H p (10) for neutrons at the irradiation position was determined to be 2,102 μSv/h, based on Monte Carlo simulation and measurement with a moderated neutron spectrometer [1], with the agreement of 13% between both methods. To test the accuracy of evaluated values, 3 batches of the OSLN dosimeters were irradiated with ~1-3 mSv neutrons.…”
Section: Neutron Irradiationmentioning
confidence: 99%
See 2 more Smart Citations