2011
DOI: 10.1016/j.watres.2011.04.047
|View full text |Cite
|
Sign up to set email alerts
|

Characterization of natural organic matter adsorption in granular activated carbon adsorbers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

12
90
1
2

Year Published

2015
2015
2023
2023

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 201 publications
(105 citation statements)
references
References 30 publications
12
90
1
2
Order By: Relevance
“…Regarding the efficiency of activated carbon, reported values ranged from 8 to 80 %, depending on the type of carbon, the water characteristics and the volume of water passed through. This process reduces mainly the low MW, hydrophilic, and biodegradable fractions of NOM (Gibert et al 2013;Velten et al 2011). In our study, the reported removal …”
Section: Dissolved Organic Carbonsupporting
confidence: 48%
“…Regarding the efficiency of activated carbon, reported values ranged from 8 to 80 %, depending on the type of carbon, the water characteristics and the volume of water passed through. This process reduces mainly the low MW, hydrophilic, and biodegradable fractions of NOM (Gibert et al 2013;Velten et al 2011). In our study, the reported removal …”
Section: Dissolved Organic Carbonsupporting
confidence: 48%
“…The LMWA fraction was always found below limit detection. This composition is in accordance with previous studies that also applied HPSEC for the fractionation of NOM after sand filtration of river water [33,34]. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 finding is in agreement with Peter-Varbanets et al [35], who also observed that "only biopolymers and the humic acid fraction of NOM were retained to some extent during filtration" of different types of water.…”
Section: Effect Of the Chemically Enhanced Bw Composition (Bw Ceb-c )supporting
confidence: 93%
“…The definitions of the individual fractions and the quantification were made via the customized software (ChromCALC, DOC- . This automated quantification has been widely adopted in a number of similar studies (Baghoth et al 2011;Gibert et al 2013;Velten et al 2011). The defined chromatogram area of each fraction and the peak heights were consistently decreased with each treatment although the extent of the reduction varied with the types of the treatment and the fraction.…”
Section: Resultsmentioning
confidence: 99%