2022
DOI: 10.1002/jms.4820
|View full text |Cite
|
Sign up to set email alerts
|

Characterization of microchannel plate detector response for the detection of native multiply charged high mass single ions in orthogonal‐time‐of‐flight mass spectrometry using a Timepix detector

Abstract: Time-of-flight (TOF) systems are one of the most widely used mass analyzers in native mass spectrometry (nMS) for the analysis of non-covalent multiply charged bio-macromolecular assemblies (MMAs). Typically, microchannel plates (MCPs) are employed for high mass native ion detection in TOF MS. MCPs are well known for their reduced detection efficiency when impinged by large slow moving ions. Here, a position-and time-sensitive Timepix (TPX) detector has been added to the back of a dual MCP stack to study the k… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(8 citation statements)
references
References 80 publications
0
8
0
Order By: Relevance
“…The significantly higher S/N ratio of TPX3 mass spectrum in Figure 2c,d compared to MCP and phosphorus screen spectrum is mainly due to the larger oversampling factor, which depends on various parameters such as MCP bias voltage, phosphor screen voltage, and camera aperture f-stop value. 20,21 Next, we evaluated the performance of TPX3CAM at higher m/z values utilizing intact IgM (∼970 kDa). IgM exists as a pentamer, in which each of the five monomers is composed of two LCs (∼25 kDa) and two HCs (∼70 kDa).…”
Section: ■ Results and Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…The significantly higher S/N ratio of TPX3 mass spectrum in Figure 2c,d compared to MCP and phosphorus screen spectrum is mainly due to the larger oversampling factor, which depends on various parameters such as MCP bias voltage, phosphor screen voltage, and camera aperture f-stop value. 20,21 Next, we evaluated the performance of TPX3CAM at higher m/z values utilizing intact IgM (∼970 kDa). IgM exists as a pentamer, in which each of the five monomers is composed of two LCs (∼25 kDa) and two HCs (∼70 kDa).…”
Section: ■ Results and Discussionmentioning
confidence: 99%
“…Smaller pixel clusters (a parameter that is related to the MCP detection efficiency) were observed for neutrals compared to the precursor ions. This is caused by a reduced ion-to-electron conversion efficiency when neutrals impact the MCP . The average pixel cluster size for metastable product neutrals and precursor ions are 3.5 and 5.5 pixels, respectively (Figure S7).…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations