Characterization of Irreversible Electroporation Ablation with a Validated Perfused Organ Model

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
21
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 27 publications
(21 citation statements)
references
References 31 publications
0
21
0
Order By: Relevance
“…A heat transfer coefficient of 30.01 W=cm 2 Á K was calculated and utilized within the model. The volumetric flow rate was calculated based on the flow rate of the internal cooling (35 ml/ min), and the cross-sectional area of the perfusion inlet stream as shown in Equation (6). Then the Reynolds and Prandtl number were determined and applied to solve for the Nusselt number for turbulent flow within a pipe (Re > 4000)…”
Section: ¼ àR á ðRruþmentioning
confidence: 99%
See 2 more Smart Citations
“…A heat transfer coefficient of 30.01 W=cm 2 Á K was calculated and utilized within the model. The volumetric flow rate was calculated based on the flow rate of the internal cooling (35 ml/ min), and the cross-sectional area of the perfusion inlet stream as shown in Equation (6). Then the Reynolds and Prandtl number were determined and applied to solve for the Nusselt number for turbulent flow within a pipe (Re > 4000)…”
Section: ¼ àR á ðRruþmentioning
confidence: 99%
“…Although they are not the main cause of cell death, temperature and current variations during IRE treatment are critical [5]. While studies have shown that higher delivered electrical energy can be associated with larger treatment zones, it also causes an increase in the protein denaturation region due to thermal side effects [6]. This creates challenges in generating a sufficiently high pulsed electric field that concurrently covers the entire region of interest, while avoiding undesirable thermal effects.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…All IRE treatments were performed in a perfused organ model [13,14]. A total of six livers were used for this study with 6 -8 treatments delivered per liver using a 4-electrode configuration electrode array.…”
Section: Electroporation Pulse Deliverymentioning
confidence: 99%
“…All experimental IRE procedures were performed on a previously validated perfused organ model [13,14]. Porcine livers were excised at a local abattoir and immediately fit with Luer-Lock connectors at the major ports of the specimen for a constant pressure flush ($90 mmHg) with three liters of modified phosphate buffer solution (conductivity of $0.8 S/ m) to mitigate thrombosis and improve overall tissue perfusion.…”
Section: Organ Preparationmentioning
confidence: 99%