2017
DOI: 10.1007/s10029-017-1638-3
|View full text |Cite|
|
Sign up to set email alerts
|

Characterization of host response, resorption, and strength properties, and performance in the presence of bacteria for fully absorbable biomaterials for soft tissue repair

Abstract: PurposeThe objective was to evaluate the host response, resorption, and strength properties, and to assess the performance in the presence of bacteria for Phasix™ Mesh (Phasix™) and Gore® Bio-A® Tissue Reinforcement (Bio-A®) in preclinical models.MethodsIn a rat model, one mesh (2 × 2 cm) was implanted subcutaneously in n = 60 rats. Animals were euthanized after 2, 4, 8, 12, 16, or 24 weeks (n = 5/mesh/time point), and implant sites were assessed for host inflammatory response and overall fibrotic repair thick… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
23
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 35 publications
(26 citation statements)
references
References 19 publications
(34 reference statements)
2
23
0
1
Order By: Relevance
“…4D) [74], to composites and to laminate patches [75]. The available data on this topic indicates that such observations are true for synthetic meshes made of both permanent [69,74] and biodegradable polymers [73].…”
Section: Guidance Based On Selection Of Appropriate Mesh Compositionmentioning
confidence: 88%
“…4D) [74], to composites and to laminate patches [75]. The available data on this topic indicates that such observations are true for synthetic meshes made of both permanent [69,74] and biodegradable polymers [73].…”
Section: Guidance Based On Selection Of Appropriate Mesh Compositionmentioning
confidence: 88%
“…The ECM thickness was measured by using the Masson trichrome stain, based on Skytec TRM-1-IFU's collagen Trichrome Stain (Connective Tissue Stain) [ 18 ] collagen deposition and quantified with ImageJ version 1.51j8 RRID: SCR_003070 [ 19 ]. Modified intra-abdominal adhesion scoring for laparoscopy [ 2 ] was used ( Table 1 ).…”
Section: Methodsmentioning
confidence: 99%
“…While not common in clean surgical procedures, when synthetic polymer mesh does become infected, the treatment often requires surgical removal of the mesh with devastating consequences as a result of the need to excise large areas of tissue (Hawn et al, 2011;Sanchez et al, 2011;Vagholkar et al, 2016). With degradable synthetic polymers, the risks appear similar until the material is degraded and absorbed and therefore can vary by the absorption time (Sahoo et al, 2017;Stoikes et al, 2017).…”
Section: Post-implantation Properties With Infectionmentioning
confidence: 99%