2018
DOI: 10.1016/j.radphyschem.2018.02.019
|View full text |Cite
|
Sign up to set email alerts
|

Characterization of ferrous-methylthymol blue-polyvinyl alcohol gel dosimeters using nuclear magnetic resonance and optical techniques

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

2
9
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 35 publications
(15 citation statements)
references
References 35 publications
2
9
0
Order By: Relevance
“…In an attempt to improve the dosimeter, poly(vinyl alcohol) (PVA) cross-linked by glutaraldehyde (GTA) was recently introduced as a matrix for the preparation of Fricke gels (Jin et al, 2012;Ruijia et al, 2010;d'Errico et al, 2017;Marini et al, 2017;Marrale et al, 2017;Boase et al, 2018;Smith et al, 2015;Gallo et al, 2019;Collura et al, 2018;Gallo et al, 2017;Eyadeh et al, 2018b;Rabaeh et al, 2018). PVA cross-linked with GTA is a hydrogel that, due to its crosslinks within the polymeric chains, absorb and retain large amount of water but do not dissolve in aqueous solutions (Hennink and van Nostrum, 2012).…”
Section: Introductionmentioning
confidence: 99%
“…In an attempt to improve the dosimeter, poly(vinyl alcohol) (PVA) cross-linked by glutaraldehyde (GTA) was recently introduced as a matrix for the preparation of Fricke gels (Jin et al, 2012;Ruijia et al, 2010;d'Errico et al, 2017;Marini et al, 2017;Marrale et al, 2017;Boase et al, 2018;Smith et al, 2015;Gallo et al, 2019;Collura et al, 2018;Gallo et al, 2017;Eyadeh et al, 2018b;Rabaeh et al, 2018). PVA cross-linked with GTA is a hydrogel that, due to its crosslinks within the polymeric chains, absorb and retain large amount of water but do not dissolve in aqueous solutions (Hennink and van Nostrum, 2012).…”
Section: Introductionmentioning
confidence: 99%
“…New developments in radiotherapy have been concerned with the study of equivalent gel dosimeters for tissues containing active chemical sensors to measure the absorbed radiation dose [ 1 , 2 , 3 , 4 , 5 , 6 ]. Gel dosimeters such as polymer gels have a range of properties like biological tissues, and are suitable alternatives compared with conventional dosimeters due to their ability in resolving three-dimensional (3D) dose distributions [ 7 , 8 , 9 , 10 , 11 ].…”
Section: Introductionmentioning
confidence: 99%
“…During the duration of the period, numerous types of dosimeters are utilized for a variety of purposes, including dyed polymeric thin plastic film dosimeters, which have been widely applied [5][6][7][8][9][10][11]. Liquid dosimeters [12][13][14][15][16][17][18], gel dosimeters [19][20][21][22] and EPR dosimeters [23][24][25]. Upon exposure to irradiation, the physical and chemical properties of the polymers change in the case of films, accordingly due to induced cross-links, chain detachments and formation of new chemical bonds [26].…”
Section: Introductionmentioning
confidence: 99%